2023-07-18 20:00:31 +00:00

106 lines
3.2 KiB
JSON

{
"id": "CVE-2023-2746",
"sourceIdentifier": "PSIRT@rockwellautomation.com",
"published": "2023-07-11T14:15:09.467",
"lastModified": "2023-07-18T19:26:41.327",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "The Rockwell Automation Enhanced HIM software contains \n\nan API that the application uses that is not protected sufficiently and uses incorrect Cross-Origin Resource Sharing (CORS) settings and, as a result, is vulnerable to a Cross Site Request Forgery (CSRF) attack. To exploit this vulnerability, a malicious user would have to convince a user to click on an untrusted link through a social engineering attack or successfully perform a Cross Site Scripting Attack (XSS). Exploitation of a CSRF could potentially lead to sensitive information disclosure and full remote access to the affected products.\n\n\n\n\n"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "CHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 9.6,
"baseSeverity": "CRITICAL"
},
"exploitabilityScore": 2.8,
"impactScore": 6.0
},
{
"source": "PSIRT@rockwellautomation.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "CHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 9.6,
"baseSeverity": "CRITICAL"
},
"exploitabilityScore": 2.8,
"impactScore": 6.0
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-352"
}
]
},
{
"source": "PSIRT@rockwellautomation.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-352"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:rockwellautomation:enhanced_him:1.001:*:*:*:*:*:*:*",
"matchCriteriaId": "51135134-B184-4E8E-8B1E-9D3B58F5E0C2"
}
]
}
]
}
],
"references": [
{
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1139760",
"source": "PSIRT@rockwellautomation.com",
"tags": [
"Permissions Required",
"Vendor Advisory"
]
}
]
}