mirror of
https://github.com/fkie-cad/nvd-json-data-feeds.git
synced 2025-06-01 19:21:37 +00:00
131 lines
4.2 KiB
JSON
131 lines
4.2 KiB
JSON
{
|
|
"id": "CVE-2023-48431",
|
|
"sourceIdentifier": "productcert@siemens.com",
|
|
"published": "2023-12-12T12:15:15.777",
|
|
"lastModified": "2023-12-14T19:37:00.257",
|
|
"vulnStatus": "Analyzed",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 2). Affected software does not correctly validate the response received by an UMC server. An attacker can use this to crash the affected software by providing and configuring a malicious UMC server or by manipulating the traffic from a legitimate UMC server (i.e. leveraging CVE-2023-48427)."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Se ha identificado una vulnerabilidad en SINEC INS (Todas las versiones < V1.0 SP2 Update 2). El software afectado no valida correctamente la respuesta recibida por un servidor UMC. Un atacante puede utilizar esto para bloquear el software afectado proporcionando y configurando un servidor UMC malicioso o manipulando el tr\u00e1fico desde un servidor UMC leg\u00edtimo (es decir, aprovechando CVE-2023-48427)."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "CHANGED",
|
|
"confidentialityImpact": "NONE",
|
|
"integrityImpact": "NONE",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 8.6,
|
|
"baseSeverity": "HIGH"
|
|
},
|
|
"exploitabilityScore": 3.9,
|
|
"impactScore": 4.0
|
|
},
|
|
{
|
|
"source": "productcert@siemens.com",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:N/I:N/A:H",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "HIGH",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "CHANGED",
|
|
"confidentialityImpact": "NONE",
|
|
"integrityImpact": "NONE",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 6.8,
|
|
"baseSeverity": "MEDIUM"
|
|
},
|
|
"exploitabilityScore": 2.2,
|
|
"impactScore": 4.0
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-754"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"source": "productcert@siemens.com",
|
|
"type": "Secondary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-754"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:sinec_ins:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "1.0",
|
|
"matchCriteriaId": "C89891C1-DFD7-4E1F-80A9-7485D86A15B5"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:sinec_ins:1.0:-:*:*:*:*:*:*",
|
|
"matchCriteriaId": "4664B195-AF14-4834-82B3-0B2C98020EB6"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:sinec_ins:1.0:sp1:*:*:*:*:*:*",
|
|
"matchCriteriaId": "75BC588E-CDF0-404E-AD61-02093A1DF343"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:sinec_ins:1.0:sp2:*:*:*:*:*:*",
|
|
"matchCriteriaId": "A334F7B4-7283-4453-BAED-D2E01B7F8A6E"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:sinec_ins:1.0:sp2_update_1:*:*:*:*:*:*",
|
|
"matchCriteriaId": "A6BEA71C-CA81-4B5D-A688-2B21E62DC351"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-077170.pdf",
|
|
"source": "productcert@siemens.com",
|
|
"tags": [
|
|
"Patch",
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |