"id": "CVE-2024-3640",
|
|
"sourceIdentifier": "PSIRT@rockwellautomation.com",
|
|
"published": "2024-05-16T16:15:10.477",
|
|
"lastModified": "2024-05-17T18:36:31.297",
|
|
"vulnStatus": "Awaiting Analysis",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "An unquoted executable path exists in the Rockwell Automation\u00a0FactoryTalk\u00ae Remote Access\u2122 possibly resulting in remote code execution if exploited. While running the FTRA installer package, the executable path is not properly quoted, which could allow a threat actor to enter a malicious executable and run it as a System user. A threat actor needs admin privileges to exploit this vulnerability."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Existe una ruta ejecutable sin comillas en Rockwell Automation FactoryTalk\u00ae Remote Access\u2122 que, si se explota, podr\u00eda provocar la ejecuci\u00f3n remota de c\u00f3digo. Mientras se ejecuta el paquete de instalaci\u00f3n de FTRA, la ruta del ejecutable no se cita correctamente, lo que podr\u00eda permitir que un actor de amenazas ingrese un ejecutable malicioso y lo ejecute como usuario del sistema. Un actor malicioso necesita privilegios de administrador para explotar esta vulnerabilidad."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV40": [
|
|
{
|
|
"source": "PSIRT@rockwellautomation.com",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "4.0",
|
|
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
|
|
"attackVector": "LOCAL",
|
|
"attackComplexity": "LOW",
|
|
"attackRequirements": "NONE",
|
|
"privilegesRequired": "HIGH",
|
|
"userInteraction": "ACTIVE",
|
|
"vulnerableSystemConfidentiality": "HIGH",
|
|
"vulnerableSystemIntegrity": "HIGH",
|
|
"vulnerableSystemAvailability": "HIGH",
|
|
"subsequentSystemConfidentiality": "NONE",
|
|
"subsequentSystemIntegrity": "NONE",
|
|
"subsequentSystemAvailability": "NONE",
|
|
"exploitMaturity": "NOT_DEFINED",
|
|
"confidentialityRequirements": "NOT_DEFINED",
|
|
"integrityRequirements": "NOT_DEFINED",
|
|
"availabilityRequirements": "NOT_DEFINED",
|
|
"modifiedAttackVector": "NOT_DEFINED",
|
|
"modifiedAttackComplexity": "NOT_DEFINED",
|
|
"modifiedAttackRequirements": "NOT_DEFINED",
|
|
"modifiedPrivilegesRequired": "NOT_DEFINED",
|
|
"modifiedUserInteraction": "NOT_DEFINED",
|
|
"modifiedVulnerableSystemConfidentiality": "NOT_DEFINED",
|
|
"modifiedVulnerableSystemIntegrity": "NOT_DEFINED",
|
|
"modifiedVulnerableSystemAvailability": "NOT_DEFINED",
|
|
"modifiedSubsequentSystemConfidentiality": "NOT_DEFINED",
|
|
"modifiedSubsequentSystemIntegrity": "NOT_DEFINED",
|
|
"modifiedSubsequentSystemAvailability": "NOT_DEFINED",
|
|
"safety": "NOT_DEFINED",
|
|
"automatable": "NOT_DEFINED",
|
|
"recovery": "NOT_DEFINED",
|
|
"valueDensity": "NOT_DEFINED",
|
|
"vulnerabilityResponseEffort": "NOT_DEFINED",
|
|
"providerUrgency": "NOT_DEFINED",
|
|
"baseScore": 7.0,
|
|
"baseSeverity": "HIGH"
|
|
}
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "PSIRT@rockwellautomation.com",
|
|
"type": "Secondary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-428"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://www.rockwellautomation.com/en-us/support/advisory.SD1671.html",
|
|
"source": "PSIRT@rockwellautomation.com"
|
|
}
|
|
]
|
|
} |