mirror of
https://github.com/fkie-cad/nvd-json-data-feeds.git
synced 2025-07-29 05:56:17 +00:00
93 lines
2.9 KiB
JSON
93 lines
2.9 KiB
JSON
{
|
|
"id": "CVE-2013-2359",
|
|
"sourceIdentifier": "hp-security-alert@hp.com",
|
|
"published": "2013-07-22T11:19:36.217",
|
|
"lastModified": "2019-10-09T23:07:32.940",
|
|
"vulnStatus": "Modified",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Unspecified vulnerability in HP System Management Homepage (SMH) before 7.2.1 allows remote authenticated users to cause a denial of service via unknown vectors, a different vulnerability than CVE-2013-2357, CVE-2013-2358, and CVE-2013-2360."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Vulnerabilidad sin especificar en HP System Management Homepage (SMH) anterior a 7.2.1, permite a usuarios autenticados remotamente provocar una denegaci\u00f3n de servicio a trav\u00e9s de vectores desconocidos. Vulnerabilidad distinta de CVE-2013-2357, CVE-2013-2358, y CVE-2013-2360."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV2": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "2.0",
|
|
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:P",
|
|
"accessVector": "NETWORK",
|
|
"accessComplexity": "LOW",
|
|
"authentication": "SINGLE",
|
|
"confidentialityImpact": "NONE",
|
|
"integrityImpact": "NONE",
|
|
"availabilityImpact": "PARTIAL",
|
|
"baseScore": 4.0
|
|
},
|
|
"baseSeverity": "MEDIUM",
|
|
"exploitabilityScore": 8.0,
|
|
"impactScore": 2.9,
|
|
"acInsufInfo": false,
|
|
"obtainAllPrivilege": false,
|
|
"obtainUserPrivilege": false,
|
|
"obtainOtherPrivilege": false,
|
|
"userInteractionRequired": false
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "NVD-CWE-noinfo"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:hp:system_management_homepage:*:*:*:*:*:*:*:*",
|
|
"versionEndIncluding": "7.2",
|
|
"matchCriteriaId": "525F8984-5088-4A9F-9EBE-031FDCF3C26C"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:hp:system_management_homepage:7.0:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "F0A2A419-3E62-4244-83D9-354755BEAA0D"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:hp:system_management_homepage:7.1:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "26EB8583-BF1A-4DA7-B560-EDDEBD4D7DA5"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay?docId=emr_na-c03839862",
|
|
"source": "hp-security-alert@hp.com",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |