2024-09-05 18:03:17 +00:00

151 lines
4.9 KiB
JSON

{
"id": "CVE-2024-4079",
"sourceIdentifier": "security@ni.com",
"published": "2024-07-23T14:15:14.353",
"lastModified": "2024-09-05T17:12:19.830",
"vulnStatus": "Analyzed",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An out of bounds read due to a missing bounds check in LabVIEW may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions."
},
{
"lang": "es",
"value": "Una lectura fuera de los l\u00edmites debido a una verificaci\u00f3n de l\u00edmites faltantes en LabVIEW puede revelar informaci\u00f3n o resultar en la ejecuci\u00f3n de c\u00f3digo arbitrario. La explotaci\u00f3n exitosa requiere que un atacante proporcione al usuario un VI especialmente manipulado. Esta vulnerabilidad afecta a LabVIEW 2024 Q1 y versiones anteriores."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
},
{
"source": "security@ni.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-125"
}
]
},
{
"source": "security@ni.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-125"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:ni:labview:*:*:*:*:*:*:*:*",
"versionEndIncluding": "2020",
"matchCriteriaId": "E9BBCA76-7B4C-4CC5-A782-489CA4223C04"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:ni:labview:2021:-:*:*:*:*:*:*",
"matchCriteriaId": "9F184512-5D11-47F4-8555-EA6FF93C106F"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:ni:labview:2021:sp1:*:*:*:*:*:*",
"matchCriteriaId": "BF28259A-30A6-4BB1-B262-A006AB74AFFA"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:ni:labview:2022:q1:*:*:*:*:*:*",
"matchCriteriaId": "4D12D6CF-802F-47BA-ADF9-9E52C071BD7F"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:ni:labview:2022:q3:*:*:*:*:*:*",
"matchCriteriaId": "340F61E5-D1ED-4C29-A894-8BC5C5B90ACE"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:ni:labview:2023:q1:*:*:*:*:*:*",
"matchCriteriaId": "D7DD2022-CFB7-4F38-B459-C1AFB55B5B68"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:ni:labview:2023:q3:*:*:*:*:*:*",
"matchCriteriaId": "18AB0B07-72FE-4861-B69D-AD2E87C5382E"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:ni:labview:2023:q3_patch2:*:*:*:*:*:*",
"matchCriteriaId": "044C4B51-C641-41F2-ACA0-834C99D63285"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:ni:labview:2024:q1:*:*:*:*:*:*",
"matchCriteriaId": "7753CCDF-BAF8-4F91-B85B-EBB2B88F6F30"
}
]
}
]
}
],
"references": [
{
"url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/out-of-bounds-read-due-to-missing-bounds-check-in-labview.html",
"source": "security@ni.com",
"tags": [
"Vendor Advisory"
]
}
]
}