"id": "CVE-2021-22763",
|
|
"sourceIdentifier": "cybersecurity@se.com",
|
|
"published": "2021-06-11T16:15:10.320",
|
|
"lastModified": "2023-11-07T03:30:24.917",
|
|
"vulnStatus": "Modified",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 (see security notification for version infromation) that could allow an attacker administrator level access to a device."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Un CWE-640: Se presenta un Mecanismo D\u00e9bil de Recuperaci\u00f3n de Contrase\u00f1as para Contrase\u00f1as Olvidadas en PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 y PowerLogic EGX300 (v\u00e9ase la notificaci\u00f3n de seguridad para obtener informaci\u00f3n sobre la versi\u00f3n) que podr\u00eda permitir a un atacante el acceso a nivel de administrador a un dispositivo"
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 9.8,
|
|
"baseSeverity": "CRITICAL"
|
|
},
|
|
"exploitabilityScore": 3.9,
|
|
"impactScore": 5.9
|
|
}
|
|
],
|
|
"cvssMetricV2": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "2.0",
|
|
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
|
|
"accessVector": "NETWORK",
|
|
"accessComplexity": "LOW",
|
|
"authentication": "NONE",
|
|
"confidentialityImpact": "COMPLETE",
|
|
"integrityImpact": "COMPLETE",
|
|
"availabilityImpact": "COMPLETE",
|
|
"baseScore": 10.0
|
|
},
|
|
"baseSeverity": "HIGH",
|
|
"exploitabilityScore": 10.0,
|
|
"impactScore": 10.0,
|
|
"acInsufInfo": false,
|
|
"obtainAllPrivilege": false,
|
|
"obtainUserPrivilege": false,
|
|
"obtainOtherPrivilege": false,
|
|
"userInteractionRequired": false
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "cybersecurity@se.com",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-640"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:schneider-electric:powerlogic_pm5560_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "2.7.8",
|
|
"matchCriteriaId": "0F8EC9ED-1E27-40B8-84A8-F66BC9FD0803"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_pm5560:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "6DDB1B76-3862-462E-B55D-875EBE508B92"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:schneider-electric:powerlogic_pm5561_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "10.7.3",
|
|
"matchCriteriaId": "EE3EFC50-39EA-4029-9713-9D191357DD29"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_pm5561:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "00D6C9E0-7DB3-4742-86F0-3430E99D1B1D"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:schneider-electric:powerlogic_pm5562_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndIncluding": "2.5.4",
|
|
"matchCriteriaId": "FDBB46A2-4EAD-41DA-AC02-5E985EB755A1"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_pm5562:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "55D7896E-3EFA-4632-B0D2-273084D56936"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:schneider-electric:powerlogic_pm5563_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "2.7.8",
|
|
"matchCriteriaId": "4E870589-0ADF-4B76-89CF-2D36F5C61CF0"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_pm5563:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "C5D4C9C4-C258-453B-85E4-893978D6C499"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:schneider-electric:powerlogic_pm8ecc_firmware:*:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "064A8AD3-3657-4E66-8A7E-397DAF03BC96"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_pm8ecc:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "38BF2D7A-492B-4A0C-A841-A245C5657192"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-02%2Chttp://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-03",
|
|
"source": "cybersecurity@se.com"
|
|
}
|
|
]
|
|
} |