René Helmke 7791f18b51 bootstrap
2023-05-16 16:09:41 +02:00

101 lines
3.4 KiB
JSON

{
"id": "CVE-2022-44457",
"sourceIdentifier": "productcert@siemens.com",
"published": "2022-11-08T11:15:12.257",
"lastModified": "2022-12-13T17:15:17.123",
"vulnStatus": "Modified",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Mendix SAML (Mendix 7 compatible) (All versions < V1.17.0), Mendix SAML (Mendix 7 compatible) (All versions >= V1.17.0 < V1.17.2), Mendix SAML (Mendix 8 compatible) (All versions < V2.3.0), Mendix SAML (Mendix 8 compatible) (All versions >= V2.3.0 < V2.3.2), Mendix SAML (Mendix 9 compatible, New Track) (All versions < V3.3.1), Mendix SAML (Mendix 9 compatible, New Track) (All versions >= V3.3.1 < V3.3.5), Mendix SAML (Mendix 9 compatible, Upgrade Track) (All versions < V3.3.0), Mendix SAML (Mendix 9 compatible, Upgrade Track) (All versions >= V3.3.0 < V3.3.4). Affected versions of the module insufficiently protect from packet capture replay, only when the not recommended, non default configuration option `'Allow Idp Initiated Authentication'` is enabled. This CVE entry describes the incomplete fix for CVE-2022-37011 in a specific non default configuration."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-294"
}
]
},
{
"source": "productcert@siemens.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-294"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:mendix:saml:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.17.0",
"matchCriteriaId": "FAE0D810-0D2A-4158-B1A1-045743098BA9"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:mendix:saml:*:*:*:*:*:*:*:*",
"versionStartIncluding": "2.3.0",
"versionEndExcluding": "2.3.2",
"matchCriteriaId": "6C2A31D3-792D-46F1-90C3-818EEE5D1C1B"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:mendix:saml:*:*:*:*:*:*:*:*",
"versionStartIncluding": "3.3.0",
"versionEndExcluding": "3.3.4",
"matchCriteriaId": "083B7407-2BCC-41DC-BF2D-2AC3298A7FAA"
}
]
}
]
}
],
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-638652.pdf",
"source": "productcert@siemens.com",
"tags": [
"Patch",
"Vendor Advisory"
]
}
]
}