2024-12-08 03:06:42 +00:00

157 lines
4.5 KiB
JSON

{
"id": "CVE-2022-23102",
"sourceIdentifier": "productcert@siemens.com",
"published": "2022-02-09T16:15:15.617",
"lastModified": "2024-11-21T06:47:59.870",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0). Affected products contain an open redirect vulnerability. An attacker could trick a valid authenticated user to the device into clicking a malicious link there by leading to phishing attacks."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en SINEMA Remote Connect Server (Todas las versiones anteriores a la versi\u00f3n V2.0). Los productos afectados contienen una vulnerabilidad de redirecci\u00f3n abierta. Un atacante podr\u00eda enga\u00f1ar a un usuario v\u00e1lido autentificado en el dispositivo para que haga clic en un enlace malicioso, lo que llevar\u00eda a ataques de phishing."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "CHANGED",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"availabilityImpact": "NONE"
},
"exploitabilityScore": 2.8,
"impactScore": 2.7
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:N",
"baseScore": 5.8,
"accessVector": "NETWORK",
"accessComplexity": "MEDIUM",
"authentication": "NONE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"availabilityImpact": "NONE"
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 8.6,
"impactScore": 4.9,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": true
}
]
},
"weaknesses": [
{
"source": "productcert@siemens.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-601"
}
]
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-601"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:sinema_remote_connect_server:*:*:*:*:*:*:*:*",
"versionEndIncluding": "2.0",
"matchCriteriaId": "380C606D-43A0-4362-9A5E-BC7320890196"
}
]
}
]
}
],
"references": [
{
"url": "http://packetstormsecurity.com/files/165966/SIEMENS-SINEMA-Remote-Connect-1.0-SP3-HF1-Open-Redirection.html",
"source": "productcert@siemens.com",
"tags": [
"Exploit",
"Third Party Advisory"
]
},
{
"url": "http://seclists.org/fulldisclosure/2022/Feb/20",
"source": "productcert@siemens.com",
"tags": [
"Exploit",
"Third Party Advisory"
]
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-654775.pdf",
"source": "productcert@siemens.com",
"tags": [
"Patch",
"Vendor Advisory"
]
},
{
"url": "http://packetstormsecurity.com/files/165966/SIEMENS-SINEMA-Remote-Connect-1.0-SP3-HF1-Open-Redirection.html",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
]
},
{
"url": "http://seclists.org/fulldisclosure/2022/Feb/20",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
]
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-654775.pdf",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
]
}
]
}