"id": "CVE-2022-27194",
|
|
"sourceIdentifier": "productcert@siemens.com",
|
|
"published": "2022-04-12T09:15:15.017",
|
|
"lastModified": "2024-11-21T06:55:23.107",
|
|
"vulnStatus": "Modified",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A vulnerability has been identified in SIMATIC PCS neo (Administration Console) (All versions < V3.1 SP1), SINETPLAN (All versions), TIA Portal (V15, V15.1, V16 and V17). The affected system cannot properly process specially crafted packets sent to port 8888/tcp. A remote attacker could exploit this vulnerability to cause a Denial-of-Service condition. The affected devices must be restarted manually."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Se ha identificado una vulnerabilidad en SIMATIC PCS neo (Consola de Administraci\u00f3n) (todas las versiones anteriores a V3.1 SP1), SINETPLAN (Todas las versiones), TIA Portal (versiones V15, V15.1, V16 y V17). El sistema afectado no puede procesar correctamente los paquetes especialmente dise\u00f1ados enviados al puerto 8888/tcp. Un atacante remoto podr\u00eda aprovechar esta vulnerabilidad para causar una condici\u00f3n de denegaci\u00f3n de servicio. Los dispositivos afectados deben reiniciarse manualmente"
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
|
|
"baseScore": 7.5,
|
|
"baseSeverity": "HIGH",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "NONE",
|
|
"integrityImpact": "NONE",
|
|
"availabilityImpact": "HIGH"
|
|
},
|
|
"exploitabilityScore": 3.9,
|
|
"impactScore": 3.6
|
|
}
|
|
],
|
|
"cvssMetricV2": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "2.0",
|
|
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
|
|
"baseScore": 7.8,
|
|
"accessVector": "NETWORK",
|
|
"accessComplexity": "LOW",
|
|
"authentication": "NONE",
|
|
"confidentialityImpact": "NONE",
|
|
"integrityImpact": "NONE",
|
|
"availabilityImpact": "COMPLETE"
|
|
},
|
|
"baseSeverity": "HIGH",
|
|
"exploitabilityScore": 10.0,
|
|
"impactScore": 6.9,
|
|
"acInsufInfo": false,
|
|
"obtainAllPrivilege": false,
|
|
"obtainUserPrivilege": false,
|
|
"obtainOtherPrivilege": false,
|
|
"userInteractionRequired": false
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "productcert@siemens.com",
|
|
"type": "Secondary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-400"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-400"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "3.1",
|
|
"matchCriteriaId": "884EC00C-1155-436D-94F4-C6F2303732CF"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:simatic_pcs_neo:3.1:-:*:*:*:*:*:*",
|
|
"matchCriteriaId": "69A8C49A-3AFD-4693-BE59-B3C75D5026E3"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:sinetplan:*:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "73C56997-3D1D-435A-8B1C-DC1023CE5715"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:15:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "A5BC801E-9D78-4CD4-A457-00ABD5991515"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:15.1:-:*:*:*:*:*:*",
|
|
"matchCriteriaId": "C36F0E09-C1BB-4ED2-9008-99DC761FDFAA"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:16:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "2E1E7FB1-03AF-4AF0-B1A6-3AF65C818596"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:17:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "7E0C3283-1FEA-4054-9D48-5F683FA9E4FF"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-711829.pdf",
|
|
"source": "productcert@siemens.com",
|
|
"tags": [
|
|
"Mitigation",
|
|
"Patch",
|
|
"Vendor Advisory"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-711829.pdf",
|
|
"source": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"tags": [
|
|
"Mitigation",
|
|
"Patch",
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |