2024-12-08 03:06:42 +00:00

150 lines
4.6 KiB
JSON

{
"id": "CVE-2022-41329",
"sourceIdentifier": "psirt@fortinet.com",
"published": "2023-03-07T17:15:12.163",
"lastModified": "2024-11-21T07:23:03.940",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An exposure of sensitive information to an unauthorized actor vulnerability [CWE-200] in Fortinet FortiProxy version 7.2.0 through 7.2.1 and 7.0.0 through 7.0.7, FortiOS version 7.2.0 through 7.2.3 and 7.0.0 through 7.0.9 allows an unauthenticated attackers to obtain sensitive logging informations on the device via crafted HTTP GET requests."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "psirt@fortinet.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"availabilityImpact": "NONE"
},
"exploitabilityScore": 3.9,
"impactScore": 1.4
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"availabilityImpact": "NONE"
},
"exploitabilityScore": 3.9,
"impactScore": 1.4
}
]
},
"weaknesses": [
{
"source": "psirt@fortinet.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-200"
}
]
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-200"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:fortinet:fortiproxy:*:*:*:*:*:*:*:*",
"versionStartIncluding": "7.0.0",
"versionEndIncluding": "7.0.8",
"matchCriteriaId": "C83139FA-7195-4171-8BC6-CC4F9379C7C9"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:fortinet:fortiproxy:*:*:*:*:*:*:*:*",
"versionStartIncluding": "7.2.0",
"versionEndIncluding": "7.2.2",
"matchCriteriaId": "57AD1A53-1D86-4707-B63C-49E1633179AD"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:*",
"versionStartIncluding": "6.2.3",
"versionEndIncluding": "6.2.13",
"matchCriteriaId": "0087A620-D709-4771-B03E-3D5F0DCBC261"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:*",
"versionStartIncluding": "6.4.0",
"versionEndIncluding": "6.4.11",
"matchCriteriaId": "A87D865A-6411-4807-81D4-6A5C052C03C9"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:*",
"versionStartIncluding": "7.0.0",
"versionEndIncluding": "7.0.9",
"matchCriteriaId": "9E775D02-7C02-40BE-A118-D874B9BBC936"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:*",
"versionStartIncluding": "7.2.0",
"versionEndIncluding": "7.2.3",
"matchCriteriaId": "813E179E-B948-4480-A5B1-B0ED562A41BC"
}
]
}
]
}
],
"references": [
{
"url": "https://fortiguard.com/psirt/FG-IR-22-364",
"source": "psirt@fortinet.com",
"tags": [
"Vendor Advisory"
]
},
{
"url": "https://fortiguard.com/psirt/FG-IR-22-364",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
]
}
]
}