"id": "CVE-2022-34438",
|
|
"sourceIdentifier": "security_alert@emc.com",
|
|
"published": "2022-10-21T18:15:09.970",
|
|
"lastModified": "2022-10-24T15:41:06.130",
|
|
"vulnStatus": "Analyzed",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Dell PowerScale OneFS, versions 8.2.x-9.4.0.x, contain a privilege context switching error. A local authenticated malicious user with high privileges could potentially exploit this vulnerability, leading to full system compromise. This impacts compliance mode clusters."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Dell PowerScale OneFS, versiones 8.2.x-9.4.0.x, contienen un error de cambio de contexto de privilegios. Un usuario malicioso autenticado localmente con altos privilegios podr\u00eda explotar esta vulnerabilidad, conllevando a un compromiso total del sistema. Esto afecta a cl\u00fasteres en modo de cumplimiento"
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
|
|
"attackVector": "LOCAL",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "HIGH",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 6.7,
|
|
"baseSeverity": "MEDIUM"
|
|
},
|
|
"exploitabilityScore": 0.8,
|
|
"impactScore": 5.9
|
|
},
|
|
{
|
|
"source": "security_alert@emc.com",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
|
|
"attackVector": "LOCAL",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "HIGH",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 6.7,
|
|
"baseSeverity": "MEDIUM"
|
|
},
|
|
"exploitabilityScore": 0.8,
|
|
"impactScore": 5.9
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-269"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:dell:emc_powerscale_onefs:*:*:*:*:*:*:*:*",
|
|
"versionStartIncluding": "9.1.0.0",
|
|
"versionEndIncluding": "9.1.0.22",
|
|
"matchCriteriaId": "3D268161-3C5F-49F8-A6FA-B9A3882FE305"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:dell:emc_powerscale_onefs:*:*:*:*:*:*:*:*",
|
|
"versionStartIncluding": "9.2.1.0",
|
|
"versionEndIncluding": "9.2.1.15",
|
|
"matchCriteriaId": "7DF679F9-228C-4CD8-9B90-9E756B7F33AE"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:dell:emc_powerscale_onefs:*:*:*:*:*:*:*:*",
|
|
"versionStartIncluding": "9.3.0.0",
|
|
"versionEndIncluding": "9.3.0.7",
|
|
"matchCriteriaId": "A4FB1971-36EC-4A19-B0DE-C11D6D5E2AA0"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:dell:emc_powerscale_onefs:*:*:*:*:*:*:*:*",
|
|
"versionStartIncluding": "9.4.0.0",
|
|
"versionEndIncluding": "9.4.0.5",
|
|
"matchCriteriaId": "0A86357E-80E6-42A3-9048-4F84D80165A4"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://www.dell.com/support/kbdoc/en-us/000204053/dsa-2022-245-dell-emc-powerscale-onefs-security-update-for-multiple-security-updates",
|
|
"source": "security_alert@emc.com",
|
|
"tags": [
|
|
"Patch",
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |