"id": "CVE-2022-34452",
|
|
"sourceIdentifier": "security_alert@emc.com",
|
|
"published": "2023-02-10T10:15:10.853",
|
|
"lastModified": "2023-11-07T03:48:42.583",
|
|
"vulnStatus": "Modified",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "\nPowerPath Management Appliance with versions 3.3, 3.2*, 3.1 & 3.0* contains sensitive information disclosure vulnerability. An Authenticated admin user can able to exploit the issue and view sensitive information stored in the logs.\n\n"
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "PowerPath Management Appliance con versiones 3.3, 3.2*, 3.1 y 3.1. 3.0* contiene una vulnerabilidad de divulgaci\u00f3n de informaci\u00f3n confidencial. Un usuario administrador autenticado puede aprovechar el problema y ver informaci\u00f3n confidencial almacenada en los registros."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "HIGH",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "LOW",
|
|
"integrityImpact": "NONE",
|
|
"availabilityImpact": "NONE",
|
|
"baseScore": 2.7,
|
|
"baseSeverity": "LOW"
|
|
},
|
|
"exploitabilityScore": 1.2,
|
|
"impactScore": 1.4
|
|
},
|
|
{
|
|
"source": "security_alert@emc.com",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "HIGH",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "LOW",
|
|
"integrityImpact": "NONE",
|
|
"availabilityImpact": "NONE",
|
|
"baseScore": 2.7,
|
|
"baseSeverity": "LOW"
|
|
},
|
|
"exploitabilityScore": 1.2,
|
|
"impactScore": 1.4
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-668"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"source": "security_alert@emc.com",
|
|
"type": "Secondary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-598"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:dell:powerpath_management_appliance:*:*:*:*:*:*:*:*",
|
|
"versionStartIncluding": "3.0",
|
|
"versionEndExcluding": "3.4",
|
|
"matchCriteriaId": "2FAF41A1-1C3A-43F0-9B38-705D0E12E34F"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://www.dell.com/support/kbdoc/en-us/000205404/dsa-2022-283-powerpath-management-appliance-security-update-for-multiple-security-vulnerabilities",
|
|
"source": "security_alert@emc.com",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |