2024-12-08 03:06:42 +00:00

234 lines
6.4 KiB
JSON

{
"id": "CVE-2020-9032",
"sourceIdentifier": "cve@mitre.org",
"published": "2020-02-17T04:15:11.640",
"lastModified": "2024-11-21T05:39:52.147",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Symmetricom SyncServer S100 2.90.70.3, S200 1.30, S250 1.25, S300 2.65.0, and S350 2.80.1 devices allow Directory Traversal via the FileName parameter to kernlog.php."
},
{
"lang": "es",
"value": "Los dispositivos Symmetricom SyncServer S100 versi\u00f3n 2.90.70.3, S200 versi\u00f3n 1.30, S250 versi\u00f3n 1.25, S300 versi\u00f3n 2.65.0 y S350 versi\u00f3n 2.80.1, permiten un Salto de Directorio por medio del par\u00e1metro FileName a un archivo kernlog.php."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"availabilityImpact": "NONE"
},
"exploitabilityScore": 3.9,
"impactScore": 2.5
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:N",
"baseScore": 6.4,
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"availabilityImpact": "NONE"
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 10.0,
"impactScore": 4.9,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-22"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:microchip:syncserver_s100_firmware:2.90.70.3:*:*:*:*:*:*:*",
"matchCriteriaId": "74360361-840A-4934-9E74-C216CDF3E257"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:microchip:syncserver_s100:-:*:*:*:*:*:*:*",
"matchCriteriaId": "BE4FB24A-DA03-4C4D-BF7C-BC5C26E9CF79"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:microchip:syncserver_s200_firmware:1.30:*:*:*:*:*:*:*",
"matchCriteriaId": "966CD4CC-FC78-47BA-BB8D-82ADDED46089"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:microchip:syncserver_s200:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CF3CDFD8-9C39-495E-820F-7379510C7A09"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:microchip:syncserver_s250_firmware:1.25:*:*:*:*:*:*:*",
"matchCriteriaId": "37E30BDA-AD90-457B-950A-589AF1428725"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:microchip:syncserver_s250:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4A583CDA-6568-4F67-8DC5-302B9644EFCE"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:microchip:syncserver_s300_firmware:2.65.0:*:*:*:*:*:*:*",
"matchCriteriaId": "68C01BFD-1C7E-4E10-B3B7-2CF87E18FD26"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:microchip:syncserver_s300:-:*:*:*:*:*:*:*",
"matchCriteriaId": "76A0C258-0C4D-4402-A0D0-61C247E24964"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:microchip:syncserver_s350_firmware:2.80.1:*:*:*:*:*:*:*",
"matchCriteriaId": "B41D65CF-FD5E-4508-9FAF-8CB7F573F650"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:microchip:syncserver_s350:-:*:*:*:*:*:*:*",
"matchCriteriaId": "29BAF33D-CB50-4AB6-9B39-DF56968CE59C"
}
]
}
]
}
],
"references": [
{
"url": "https://sku11army.blogspot.com/2020/01/symmetricom-syncserver.html",
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
]
},
{
"url": "https://sku11army.blogspot.com/2020/01/symmetricom-syncserver.html",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
]
}
]
}