René Helmke 7791f18b51 bootstrap
2023-05-16 16:09:41 +02:00

182 lines
4.9 KiB
JSON

{
"id": "CVE-2020-14472",
"sourceIdentifier": "cve@mitre.org",
"published": "2020-06-24T17:15:11.790",
"lastModified": "2021-12-21T01:29:02.553",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "On Draytek Vigor3900, Vigor2960, and Vigor 300B devices before 1.5.1.1, there are some command-injection vulnerabilities in the mainfunction.cgi file."
},
{
"lang": "es",
"value": "DrayTek Vigor3900, Vigor2960 y Vigor300B anteriores a 1.5.1.1, tiene algunas vulnerabilidades de inyecci\u00f3n de comandos en el archivo mainfunction.cgi."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5
},
"baseSeverity": "HIGH",
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-77"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:draytek:vigor300b_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.5.1.1",
"matchCriteriaId": "145682DB-5518-43FD-8419-E0232566F3C4"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:draytek:vigor300b:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DA5B988D-ED1A-4CBF-8B34-C5B03A55ED52"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:draytek:vigor2960_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.5.1.1",
"matchCriteriaId": "2AD4768B-73CE-4185-B676-71E1791F8D47"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:draytek:vigor2960:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8FDA3905-67DD-4F31-AFCF-014F1D7CCC1F"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:draytek:vigor3900_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.5.1.1",
"matchCriteriaId": "9C71C769-6CEB-4377-85FB-8719626D04B5"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:draytek:vigor3900:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FEECFBBC-5551-4135-9194-4216A39B04B9"
}
]
}
]
}
],
"references": [
{
"url": "https://gist.github.com/Cossack9989/fa9718434ceee4e6d4f6b0ad672c10f1",
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
]
},
{
"url": "https://gist.github.com/WinMin/46165779215f1d47ec257210428c0240",
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
]
}
]
}