René Helmke 7791f18b51 bootstrap
2023-05-16 16:09:41 +02:00

105 lines
3.3 KiB
JSON

{
"id": "CVE-2009-1798",
"sourceIdentifier": "cve@mitre.org",
"published": "2009-12-28T19:30:00.267",
"lastModified": "2010-06-29T04:00:00.000",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "Multiple cross-site scripting (XSS) vulnerabilities on the Network Management Card (NMC) on American Power Conversion (APC) Switched Rack PDU (aka Rack Mount Power Distribution) devices and other devices allow remote attackers to inject arbitrary web script or HTML via unspecified vectors. NOTE: the login_username vector for Forms/login1 is already covered by CVE-2009-4406."
},
{
"lang": "es",
"value": "M\u00faltiples vulnerabilidades de secuencias de comandos en sitios cruzados (XSS) en Network Management Card (NMC) para dispositivos American Power Conversion (APC) Switched Rack PDU (tambi\u00e9n conocido como Rack Mount Power Distribution) y otros dispositivos permite a atacantes remotos inyectar secuencias de comandos web o HTML de su elecci\u00f3n medisnte vectores no especificados. NOTA: el vector login_username para Forms/login1 est\u00e1 ya cubierto por CVE-2009-4406."
}
],
"metrics": {
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
"accessVector": "NETWORK",
"accessComplexity": "MEDIUM",
"authentication": "NONE",
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"availabilityImpact": "NONE",
"baseScore": 4.3
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": true
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-79"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:h:apc:network_management_card:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B549D2FA-E74F-4674-8D2E-B8C605EE0FD2"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:h:apc:switched_rack_pdu:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6CCDBFB0-6726-4988-A59E-234C88EB04D0"
}
]
}
]
}
],
"references": [
{
"url": "http://holisticinfosec.org/content/view/111/45/",
"source": "cve@mitre.org"
},
{
"url": "http://nam-en.apc.com/cgi-bin/nam_en.cfg/php/enduser/std_adp.php?p_faqid=10887",
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
]
},
{
"url": "http://www.kb.cert.org/vuls/id/166739",
"source": "cve@mitre.org",
"tags": [
"US Government Resource"
]
}
]
}