"id": "CVE-2021-20094",
"sourceIdentifier": "vulnreport@tenable.com",
"published": "2021-06-16T12:15:12.073",
"lastModified": "2022-05-13T17:30:28.603",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "A denial of service vulnerability exists in Wibu-Systems CodeMeter versions < 7.21a. An unauthenticated remote attacker can exploit this issue to crash the CodeMeter Runtime Server."
},
{
"lang": "es",
"value": "Se presenta una vulnerabilidad de denegaci\u00f3n de servicio en las de Wibu-Systems CodeMeter versiones anteriores a 7.21a. Un atacante remoto no autenticado puede explotar este problema para bloquear el CodeMeter Runtime Server"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-125"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:wibu:codemeter:*:*:*:*:*:*:*:*",
"versionEndExcluding": "7.21a",
"matchCriteriaId": "E4D83EED-5237-4A45-82AA-5370A6B9D0D9"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:pss_cape:-:*:*:*:*:*:*:*",
"matchCriteriaId": "890BA38B-38CD-4B6D-96E8-A786CFFE4C35"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:siemens:sicam_230_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "ACC0968E-7082-4FBF-AEC0-91B280DA2A8C"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:siemens:sicam_230:-:*:*:*:*:*:*:*",
"matchCriteriaId": "702949EB-ED2D-4E85-802B-93EEA4FA939E"
}
]
}
]
}
],
"references": [
{
"url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210423-02.pdf",
"source": "vulnreport@tenable.com",
"tags": [
"Mitigation",
"Vendor Advisory"
]
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-675303.pdf",
"source": "vulnreport@tenable.com",
"tags": [
"Patch",
"Third Party Advisory"
]
},
{
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-210-02",
"source": "vulnreport@tenable.com",
"tags": [
"Third Party Advisory",
"US Government Resource"
]
},
{
"url": "https://www.tenable.com/security/research/tra-2021-24",
"source": "vulnreport@tenable.com",
"tags": [
"Exploit",
"Patch",
"Third Party Advisory"
]
}
]
}