mirror of
https://github.com/fkie-cad/nvd-json-data-feeds.git
synced 2025-05-28 09:11:28 +00:00
135 lines
4.1 KiB
JSON
135 lines
4.1 KiB
JSON
{
|
|
"id": "CVE-2021-21514",
|
|
"sourceIdentifier": "security_alert@emc.com",
|
|
"published": "2021-03-02T16:15:12.987",
|
|
"lastModified": "2021-03-09T17:30:07.837",
|
|
"vulnStatus": "Analyzed",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Dell EMC OpenManage Server Administrator (OMSA) versions 9.5 and prior contain a path traversal vulnerability. A remote user with admin privileges could potentially exploit this vulnerability to view arbitrary files on the target system by sending a specially crafted URL request."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Dell EMC OpenManage Server Administrator (OMSA) versiones 9.5 y anteriores, contienen una vulnerabilidad de salto de ruta. Un usuario remoto con privilegios de administrador podr\u00eda explotar esta vulnerabilidad para visualizar archivos arbitrarios en el sistema de destino por medio del env\u00edo de una petici\u00f3n de URL especialmente dise\u00f1ada"
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "HIGH",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "NONE",
|
|
"availabilityImpact": "NONE",
|
|
"baseScore": 4.9,
|
|
"baseSeverity": "MEDIUM"
|
|
},
|
|
"exploitabilityScore": 1.2,
|
|
"impactScore": 3.6
|
|
},
|
|
{
|
|
"source": "security_alert@emc.com",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "HIGH",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "NONE",
|
|
"availabilityImpact": "NONE",
|
|
"baseScore": 4.9,
|
|
"baseSeverity": "MEDIUM"
|
|
},
|
|
"exploitabilityScore": 1.2,
|
|
"impactScore": 3.6
|
|
}
|
|
],
|
|
"cvssMetricV2": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "2.0",
|
|
"vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
|
|
"accessVector": "NETWORK",
|
|
"accessComplexity": "LOW",
|
|
"authentication": "SINGLE",
|
|
"confidentialityImpact": "PARTIAL",
|
|
"integrityImpact": "NONE",
|
|
"availabilityImpact": "NONE",
|
|
"baseScore": 4.0
|
|
},
|
|
"baseSeverity": "MEDIUM",
|
|
"exploitabilityScore": 8.0,
|
|
"impactScore": 2.9,
|
|
"acInsufInfo": false,
|
|
"obtainAllPrivilege": false,
|
|
"obtainUserPrivilege": false,
|
|
"obtainOtherPrivilege": false,
|
|
"userInteractionRequired": false
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-22"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"source": "security_alert@emc.com",
|
|
"type": "Secondary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-22"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:dell:openmanage_server_administrator:*:*:*:*:*:*:*:*",
|
|
"versionEndIncluding": "9.5.0",
|
|
"matchCriteriaId": "91F40141-2692-4207-AE06-38A788F6E518"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://www.dell.com/support/kbdoc/en-us/000183670/dsa-2021-040-dell-emc-openmanage-server-administrator-omsa-security-update-for-multiple-vulnerabilities",
|
|
"source": "security_alert@emc.com",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |