"id": "CVE-2021-22824",
"sourceIdentifier": "cybersecurity@se.com",
"published": "2022-02-11T18:15:09.617",
"lastModified": "2022-02-18T18:29:45.430",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in denial of service, due to missing length check on user-supplied data from a constructed message received on the network. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)"
},
{
"lang": "es",
"value": "Una CWE-120: Se presenta una vulnerabilidad de Copia del B\u00fafer sin Comprobar el Tama\u00f1o de la Entrada que podr\u00eda resultar en una denegaci\u00f3n de servicio, debido a una falta de comprobaci\u00f3n de la longitud de los datos suministrados por el usuario de un mensaje construido recibido en la red. Producto afectado: Interactive Graphical SCADA System Data Collector (dc.exe) (versiones V15.0.0.21320 y anteriores)"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-120"
}
]
},
{
"source": "cybersecurity@se.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-120"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:schneider-electric:interactive_graphical_scada_system_data_collector:*:*:*:*:*:*:*:*",
"versionEndIncluding": "15.0.0.21320",
"matchCriteriaId": "BCC36B69-9234-4136-8A41-4AF378DD9842"
}
]
}
]
}
],
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-01",
"source": "cybersecurity@se.com",
"tags": [
"Patch",
"Vendor Advisory"
]
}
]
}