mirror of
https://github.com/fkie-cad/nvd-json-data-feeds.git
synced 2025-05-28 17:21:36 +00:00
157 lines
5.2 KiB
JSON
157 lines
5.2 KiB
JSON
{
|
|
"id": "CVE-2021-26724",
|
|
"sourceIdentifier": "prodsec@nozominetworks.com",
|
|
"published": "2021-02-22T21:15:19.787",
|
|
"lastModified": "2021-02-26T17:38:17.390",
|
|
"vulnStatus": "Analyzed",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "OS Command Injection vulnerability when changing date settings or hostname using web GUI of Nozomi Networks Guardian and CMC allows authenticated administrators to perform remote code execution. This issue affects: Nozomi Networks Guardian 20.0.7.3 version 20.0.7.3 and prior versions. Nozomi Networks CMC 20.0.7.3 version 20.0.7.3 and prior versions."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Una vulnerabilidad de inyecci\u00f3n de comandos del Sistema Operativo cuando se cambia la configuraci\u00f3n de fecha o el nombre de host usando la GUI web de Nozomi Networks Guardian y CMC, permite a administradores autenticados llevar a cabo una ejecuci\u00f3n de c\u00f3digo remota . Este problema afecta a: Nozomi Networks Guardian versi\u00f3n 20.0.7.3 versi\u00f3n 20.0.7.3 y versiones anteriores. Nozomi Networks CMC versi\u00f3n 20.0.7.3 versi\u00f3n 20.0.7.3 y versiones anteriores"
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "HIGH",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 7.2,
|
|
"baseSeverity": "HIGH"
|
|
},
|
|
"exploitabilityScore": 1.2,
|
|
"impactScore": 5.9
|
|
},
|
|
{
|
|
"source": "prodsec@nozominetworks.com",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "HIGH",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 7.2,
|
|
"baseSeverity": "HIGH"
|
|
},
|
|
"exploitabilityScore": 1.2,
|
|
"impactScore": 5.9
|
|
}
|
|
],
|
|
"cvssMetricV2": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "2.0",
|
|
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
|
|
"accessVector": "NETWORK",
|
|
"accessComplexity": "LOW",
|
|
"authentication": "SINGLE",
|
|
"confidentialityImpact": "COMPLETE",
|
|
"integrityImpact": "COMPLETE",
|
|
"availabilityImpact": "COMPLETE",
|
|
"baseScore": 9.0
|
|
},
|
|
"baseSeverity": "HIGH",
|
|
"exploitabilityScore": 8.0,
|
|
"impactScore": 10.0,
|
|
"acInsufInfo": false,
|
|
"obtainAllPrivilege": false,
|
|
"obtainUserPrivilege": false,
|
|
"obtainOtherPrivilege": false,
|
|
"userInteractionRequired": false
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-78"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"source": "prodsec@nozominetworks.com",
|
|
"type": "Secondary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-78"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:nozominetworks:central_management_control:*:*:*:*:*:*:*:*",
|
|
"versionStartIncluding": "19.0.0",
|
|
"versionEndIncluding": "19.0.12",
|
|
"matchCriteriaId": "6CEDEFB4-AD39-4211-BC5C-0B698E979ACB"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:nozominetworks:central_management_control:*:*:*:*:*:*:*:*",
|
|
"versionStartIncluding": "20.0.0.0",
|
|
"versionEndExcluding": "20.0.7.4",
|
|
"matchCriteriaId": "928EC60A-002B-4E8C-ABD5-E617EA853EEF"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:nozominetworks:guardian:*:*:*:*:*:*:*:*",
|
|
"versionStartIncluding": "19.0.0",
|
|
"versionEndExcluding": "19.0.12",
|
|
"matchCriteriaId": "06B9E3D4-EEA8-4314-B0F5-5C47431545C2"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:nozominetworks:guardian:*:*:*:*:*:*:*:*",
|
|
"versionStartIncluding": "20.0.0.0",
|
|
"versionEndExcluding": "20.0.7.4",
|
|
"matchCriteriaId": "77035537-8C15-4130-A2B8-88D4F082BADE"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://security.nozominetworks.com/NN-2021:1-01",
|
|
"source": "prodsec@nozominetworks.com",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |