René Helmke 7791f18b51 bootstrap
2023-05-16 16:09:41 +02:00

128 lines
3.8 KiB
JSON

{
"id": "CVE-2021-26733",
"sourceIdentifier": "prodsec@nozominetworks.com",
"published": "2022-10-24T14:15:48.423",
"lastModified": "2023-02-03T14:47:07.270",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "A broken access control vulnerability in the FirstReset_handler_func function of spx_restservice allows an attacker to arbitrarily send reboot commands to the BMC, causing a Denial-of-Service (DoS) condition. This issue affects: Lanner Inc IAC-AST2500A standard firmware version 1.10.0."
},
{
"lang": "es",
"value": "Una vulnerabilidad de control de acceso rota en la funci\u00f3n FirstReset_handler_func de spx_restservice permite a un atacante enviar arbitrariamente comandos de reinicio al BMC, causando una condici\u00f3n de Denegaci\u00f3n de Servicio (DoS). Este problema afecta a: Lanner Inc IAC-AST2500A versi\u00f3n de firmware est\u00e1ndar 1.10.0"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6
},
{
"source": "prodsec@nozominetworks.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "LOW",
"baseScore": 5.3,
"baseSeverity": "MEDIUM"
},
"exploitabilityScore": 3.9,
"impactScore": 1.4
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "NVD-CWE-Other"
}
]
},
{
"source": "prodsec@nozominetworks.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-284"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:lannerinc:iac-ast2500a_firmware:1.10.0:*:*:*:*:*:*:*",
"matchCriteriaId": "8DD71184-078B-4B7E-BCB5-11E55B5928B7"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:lannerinc:iac-ast2500a:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9007683B-45DA-471A-9CCB-A587DED8D973"
}
]
}
]
}
],
"references": [
{
"url": "https://www.nozominetworks.com/blog/vulnerabilities-in-bmc-firmware-affect-ot-iot-device-security-part-1/",
"source": "prodsec@nozominetworks.com",
"tags": [
"Third Party Advisory"
]
},
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories/cve-2021-26733/",
"source": "prodsec@nozominetworks.com",
"tags": [
"Third Party Advisory"
]
}
]
}