René Helmke 7791f18b51 bootstrap
2023-05-16 16:09:41 +02:00

117 lines
3.7 KiB
JSON

{
"id": "CVE-2021-31518",
"sourceIdentifier": "security@trendmicro.com",
"published": "2021-05-05T15:15:08.460",
"lastModified": "2021-05-11T19:05:43.670",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "Trend Micro Home Network Security 6.5.599 and earlier is vulnerable to a file-parsing vulnerability which could allow an attacker to exploit the vulnerability and cause a denial-of-service to the device. This vulnerability is similar, but not identical to CVE-2021-31517."
},
{
"lang": "es",
"value": "Trend Micro Home Network Security versiones 6.5.599 y anteriores, es susceptible a una vulnerabilidad de an\u00e1lisis de archivos que podr\u00eda permitir a un atacante explotar la vulnerabilidad y causar una denegaci\u00f3n de servicio en el dispositivo. Esta vulnerabilidad es similar, pero no id\u00e9ntica a CVE-2021-31517"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8
},
"baseSeverity": "HIGH",
"exploitabilityScore": 10.0,
"impactScore": 6.9,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:trendmicro:home_network_security:*:*:*:en:*:*:*:*",
"versionEndIncluding": "6.5.599",
"matchCriteriaId": "D2A6C520-2F92-4DD2-85C0-110BA87E5792"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:trendmicro:home_network_security:*:*:*:ja:*:*:*:*",
"versionEndIncluding": "6.5.599",
"matchCriteriaId": "1DD965FE-1066-4C12-BB31-FC5B536A8050"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:trendmicro:home_network_security:*:*:*:zh:*:*:*:*",
"versionEndIncluding": "6.5.599",
"matchCriteriaId": "F53D6A33-030D-44C0-9E05-98BF50B7F1E0"
}
]
}
]
}
],
"references": [
{
"url": "https://helpcenter.trendmicro.com/en-us/article/TMKA-10312",
"source": "security@trendmicro.com",
"tags": [
"Vendor Advisory"
]
}
]
}