René Helmke 7791f18b51 bootstrap
2023-05-16 16:09:41 +02:00

120 lines
4.0 KiB
JSON

{
"id": "CVE-2021-33709",
"sourceIdentifier": "productcert@siemens.com",
"published": "2021-07-13T11:15:09.750",
"lastModified": "2021-07-20T19:26:55.653",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Teamcenter Active Workspace V4 (All versions < V4.3.9), Teamcenter Active Workspace V5.0 (All versions < V5.0.7), Teamcenter Active Workspace V5.1 (All versions < V5.1.4). By sending malformed requests, a remote attacker could leak an application token due to an error not properly handled by the system."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en Teamcenter Active Workspace versiones V4 (Todas las versiones anteriores a V4.3.9), Teamcenter Active Workspace versiones V5.0 (Todas las versiones anteriores a V5.0.7), Teamcenter Active Workspace versiones V5.1 (Todas las versiones anteriores a V5.1.4). Mediante el env\u00edo de peticiones malformadas, un atacante remoto podr\u00eda filtrar un token de la aplicaci\u00f3n debido a un error manejado inapropiadamente por el sistema"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM"
},
"exploitabilityScore": 2.8,
"impactScore": 1.4
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "SINGLE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"availabilityImpact": "NONE",
"baseScore": 4.0
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 8.0,
"impactScore": 2.9,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "productcert@siemens.com",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-200"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:teamcenter_active_workspace:*:*:*:*:*:*:*:*",
"versionStartIncluding": "4.0.0",
"versionEndExcluding": "4.3.9",
"matchCriteriaId": "E2BB7B04-DD2F-42A8-89ED-0A014C768061"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:teamcenter_active_workspace:*:*:*:*:*:*:*:*",
"versionStartIncluding": "5.0.0",
"versionEndExcluding": "5.0.7",
"matchCriteriaId": "3752E0F7-4A3C-411B-9469-443D8C815629"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:teamcenter_active_workspace:*:*:*:*:*:*:*:*",
"versionStartIncluding": "5.1.0",
"versionEndExcluding": "5.1.4",
"matchCriteriaId": "4785E6FA-C094-49FD-BF8E-6E41EFF14467"
}
]
}
]
}
],
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-622535.pdf",
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
]
}
]
}