René Helmke 7791f18b51 bootstrap
2023-05-16 16:09:41 +02:00

122 lines
3.9 KiB
JSON

{
"id": "CVE-2021-33717",
"sourceIdentifier": "productcert@siemens.com",
"published": "2021-08-10T11:15:09.040",
"lastModified": "2021-08-18T13:46:06.787",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions < V13.2.0.1), Teamcenter Visualization (All versions < V13.2.0.1). When parsing specially crafted CGM Files, a NULL pointer deference condition could cause the application to crash. The application must be restarted to restore the service. An attacker could leverage this vulnerability to cause a Denial-of-Service condition in the application."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones anteriores a V13.2.0.1), Teamcenter Visualization (Todas las versiones anteriores a V13.2.0.1). Cuando se analizan archivos CGM especialmente dise\u00f1ados, una condici\u00f3n de deferencia de puntero NULL podr\u00eda causar el bloqueo de la aplicaci\u00f3n. La aplicaci\u00f3n debe ser reiniciada para restaurar el servicio. Un atacante podr\u00eda aprovechar esta vulnerabilidad para causar una condici\u00f3n de Denegaci\u00f3n de Servicio en la aplicaci\u00f3n"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "HIGH",
"baseScore": 5.5,
"baseSeverity": "MEDIUM"
},
"exploitabilityScore": 1.8,
"impactScore": 3.6
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:P",
"accessVector": "NETWORK",
"accessComplexity": "MEDIUM",
"authentication": "NONE",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 4.3
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": true
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-476"
}
]
},
{
"source": "productcert@siemens.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-476"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*",
"versionEndExcluding": "13.2.0.1",
"matchCriteriaId": "C811E8B2-CA0C-4A71-A803-A30C4DAF1476"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"versionEndExcluding": "13.2.0.1",
"matchCriteriaId": "87BB2370-46C4-4BEC-8189-1F7FE4C1E12D"
}
]
}
]
}
],
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf",
"source": "productcert@siemens.com",
"tags": [
"Patch",
"Vendor Advisory"
]
}
]
}