René Helmke 7791f18b51 bootstrap
2023-05-16 16:09:41 +02:00

121 lines
3.3 KiB
JSON

{
"id": "CVE-2021-36165",
"sourceIdentifier": "cve@mitre.org",
"published": "2021-09-28T10:15:08.217",
"lastModified": "2022-07-12T17:42:04.277",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "RICON Industrial Cellular Router S9922L 16.10.3(3794) is affected by cleartext storage of sensitive information and sends username and password as base64."
},
{
"lang": "es",
"value": "El router celular industrial S9922L versi\u00f3n 16.10.3(3794) de RICON est\u00e1 afectado por el almacenamiento en texto sin cifrar de informaci\u00f3n confidencial y env\u00eda el nombre de usuario y la contrase\u00f1a como base64"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM"
},
"exploitabilityScore": 3.9,
"impactScore": 1.4
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.0
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-312"
},
{
"lang": "en",
"value": "CWE-319"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:riconmobile:s9922l_firmware:16.10.3\\(3794\\):*:*:*:*:*:*:*",
"matchCriteriaId": "C1415E94-6485-4C8A-B039-96394328D1AF"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:riconmobile:s9922l:1.0:*:*:*:*:*:*:*",
"matchCriteriaId": "66D65C60-8119-46A3-B246-9D61E66E7BC5"
}
]
}
]
}
],
"references": [
{
"url": "https://yunus-shn.medium.com/ricon-industrial-cellular-router-cleartext-credentials-e236052415d",
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
]
}
]
}