René Helmke 7791f18b51 bootstrap
2023-05-16 16:09:41 +02:00

117 lines
3.5 KiB
JSON

{
"id": "CVE-2021-37911",
"sourceIdentifier": "twcert@cert.org.tw",
"published": "2021-08-30T15:15:07.917",
"lastModified": "2021-09-10T15:31:18.523",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "The management interface of BenQ smart wireless conference projector does not properly control user's privilege. Attackers can access any system directory of this device through the interface and execute arbitrary commands if he enters the local subnetwork."
},
{
"lang": "es",
"value": "La interfaz de administraci\u00f3n del proyector de BenQ smart wireless conference projector, no controla apropiadamente los privilegios del usuario. Unos atacantes pueden acceder a cualquier directorio del sistema de este dispositivo mediante la interfaz y ejecutar comandos arbitrario si entra en la subred local."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "twcert@cert.org.tw",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "ADJACENT_NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C",
"accessVector": "ADJACENT_NETWORK",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"availabilityImpact": "COMPLETE",
"baseScore": 8.3
},
"baseSeverity": "HIGH",
"exploitabilityScore": 6.5,
"impactScore": 10.0,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "twcert@cert.org.tw",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-269"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:benq:eh600_firmware:*:*:*:*:*:*:*:*",
"versionEndIncluding": "01.00.30.00",
"matchCriteriaId": "C440F517-78CD-4F4D-A08E-F44EC7706503"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:benq:eh600:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4ABF87E7-270A-445A-8E5B-46944ECC2342"
}
]
}
]
}
],
"references": [
{
"url": "https://www.twcert.org.tw/tw/cp-132-5047-7ef35-1.html",
"source": "twcert@cert.org.tw",
"tags": [
"Third Party Advisory"
]
}
]
}