"id": "CVE-2021-41545",
|
|
"sourceIdentifier": "productcert@siemens.com",
|
|
"published": "2022-05-10T11:15:07.840",
|
|
"lastModified": "2022-05-19T17:09:19.667",
|
|
"vulnStatus": "Analyzed",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A vulnerability has been identified in Desigo DXR2 (All versions < V01.21.142.5-22), Desigo PXC3 (All versions < V01.21.142.4-18), Desigo PXC4 (All versions < V02.20.142.10-10884), Desigo PXC5 (All versions < V02.20.142.10-10884). When the controller receives a specific BACnet protocol packet, an exception causes the BACnet communication function to go into a \u201cout of work\u201d state and could result in the controller going into a \u201cfactory reset\u201d state."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Se ha identificado una vulnerabilidad en Desigo DXR2 (Todas las versiones anteriores a V01.21.142.5-22), Desigo PXC3 (Todas las versiones anteriores a V01.21.142.4-18), Desigo PXC4 (Todas las versiones anteriores a V02.20.142.10-10884), Desigo PXC5 (Todas las versiones anteriores a V02.20.142.10-10884). Cuando el controlador recibe un paquete de protocolo BACnet espec\u00edfico, una excepci\u00f3n causa que la funci\u00f3n de comunicaci\u00f3n BACnet pase a un estado \"out of work\" y podr\u00eda resultar que el controlador pase a un estado \"factory reset\""
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "NONE",
|
|
"integrityImpact": "NONE",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 7.5,
|
|
"baseSeverity": "HIGH"
|
|
},
|
|
"exploitabilityScore": 3.9,
|
|
"impactScore": 3.6
|
|
}
|
|
],
|
|
"cvssMetricV2": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "2.0",
|
|
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
|
|
"accessVector": "NETWORK",
|
|
"accessComplexity": "LOW",
|
|
"authentication": "NONE",
|
|
"confidentialityImpact": "NONE",
|
|
"integrityImpact": "NONE",
|
|
"availabilityImpact": "PARTIAL",
|
|
"baseScore": 5.0
|
|
},
|
|
"baseSeverity": "MEDIUM",
|
|
"exploitabilityScore": 10.0,
|
|
"impactScore": 2.9,
|
|
"acInsufInfo": false,
|
|
"obtainAllPrivilege": false,
|
|
"obtainUserPrivilege": false,
|
|
"obtainOtherPrivilege": false,
|
|
"userInteractionRequired": false
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "NVD-CWE-noinfo"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"source": "productcert@siemens.com",
|
|
"type": "Secondary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-248"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:siemens:desigo_dxr2_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "01.21.142.5-22",
|
|
"matchCriteriaId": "5B50EDDC-4B68-416E-B8BE-58399A90FE44"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:siemens:desigo_dxr2:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "21EDDCD7-3B64-410E-A294-0F5F65849F4E"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:siemens:desigo_pxc3_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "01.21.142.4-18",
|
|
"matchCriteriaId": "D7ABEE98-3FF4-4E7C-B1CD-0E5E56E437FF"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:siemens:desigo_pxc3:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "373009ED-3AE4-4F0B-940D-8E82668C3FF3"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:siemens:desigo_pxc4_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "02.20.142.10-10884",
|
|
"matchCriteriaId": "84D6AF5F-AD6D-4A30-9D72-31A3BA2A5DC3"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:siemens:desigo_pxc4:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "0327220F-B5E6-4722-AEB2-BC4C21F1060D"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:siemens:desigo_pxc5_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "02.20.142.10-10884",
|
|
"matchCriteriaId": "7B710014-DE57-43C2-9BFE-A4F8AF6542D5"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:siemens:desigo_pxc5:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "C4E2A7F6-B6E5-4230-8F13-64745C434A71"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-662649.pdf",
|
|
"source": "productcert@siemens.com",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |