"id": "CVE-2021-42015",
|
|
"sourceIdentifier": "productcert@siemens.com",
|
|
"published": "2021-11-09T12:15:10.467",
|
|
"lastModified": "2021-11-12T20:25:10.053",
|
|
"vulnStatus": "Analyzed",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.26), Mendix Applications using Mendix 8 (All versions < V8.18.12), Mendix Applications using Mendix 9 (All versions < V9.6.1). Applications built with affected versions of Mendix Studio Pro do not prevent file documents from being cached when files are opened or downloaded using a browser. This could allow a local attacker to read those documents by exploring the browser cache."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Se ha identificado una vulnerabilidad en las aplicaciones Mendix que usan Mendix versi\u00f3n 7 (Todas las versiones anteriores a V7.23.26), las aplicaciones Mendix que usan Mendix versi\u00f3n 8 (Todas las versiones anteriores a V8.18.12), las aplicaciones Mendix que usan Mendix versi\u00f3n 9 (Todas las versiones anteriores a V9.6.1). Las aplicaciones construidas con las versiones afectadas de Mendix Studio Pro no evitan que los documentos de archivo se almacenen en la cach\u00e9 cuando los archivos son abiertos o descargados usando un navegador. Esto podr\u00eda permitir a un atacante local leer esos documentos explorando la cach\u00e9 del navegador"
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
|
|
"attackVector": "LOCAL",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "LOW",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "NONE",
|
|
"availabilityImpact": "NONE",
|
|
"baseScore": 5.5,
|
|
"baseSeverity": "MEDIUM"
|
|
},
|
|
"exploitabilityScore": 1.8,
|
|
"impactScore": 3.6
|
|
}
|
|
],
|
|
"cvssMetricV2": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "2.0",
|
|
"vectorString": "AV:L/AC:M/Au:N/C:P/I:N/A:N",
|
|
"accessVector": "LOCAL",
|
|
"accessComplexity": "MEDIUM",
|
|
"authentication": "NONE",
|
|
"confidentialityImpact": "PARTIAL",
|
|
"integrityImpact": "NONE",
|
|
"availabilityImpact": "NONE",
|
|
"baseScore": 1.9
|
|
},
|
|
"baseSeverity": "LOW",
|
|
"exploitabilityScore": 3.4,
|
|
"impactScore": 2.9,
|
|
"acInsufInfo": false,
|
|
"obtainAllPrivilege": false,
|
|
"obtainUserPrivilege": false,
|
|
"obtainOtherPrivilege": false,
|
|
"userInteractionRequired": false
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "productcert@siemens.com",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-525"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:mendix:mendix:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "7.23.26",
|
|
"matchCriteriaId": "BDEBAEC6-E146-44FF-B56F-92AE868BB169"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:mendix:mendix:*:*:*:*:*:*:*:*",
|
|
"versionStartIncluding": "8.0.0",
|
|
"versionEndExcluding": "8.18.12",
|
|
"matchCriteriaId": "B53A7584-33F9-4461-979F-0CD2E362C3AC"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:mendix:mendix:*:*:*:*:*:*:*:*",
|
|
"versionStartIncluding": "9.0.0",
|
|
"versionEndExcluding": "9.6.1",
|
|
"matchCriteriaId": "A0B9BB81-9DC1-4013-A764-FC03CB6AFC87"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-338732.pdf",
|
|
"source": "productcert@siemens.com",
|
|
"tags": [
|
|
"Patch",
|
|
"Third Party Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |