René Helmke 7791f18b51 bootstrap
2023-05-16 16:09:41 +02:00

334 lines
9.4 KiB
JSON

{
"id": "CVE-2021-45650",
"sourceIdentifier": "cve@mitre.org",
"published": "2021-12-26T01:15:20.103",
"lastModified": "2022-01-06T15:55:45.193",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by disclosure of sensitive information. This affects R7000 before 1.0.11.110, R7900 before 1.0.4.30, R8000 before 1.0.4.62, RS400 before 1.5.1.80, R6400v2 before 1.0.4.102, R7000P before 1.3.2.126, R6700v3 before 1.0.4.102, and R6900P before 1.3.2.126."
},
{
"lang": "es",
"value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una divulgaci\u00f3n de informaci\u00f3n confidencial. Esto afecta a R7000 versiones anteriores a 1.0.11.110, R7900 versiones anteriores a 1.0.4.30, R8000 versiones anteriores a 1.0.4.62, RS400 versiones anteriores a 1.5.1.80, R6400v2 versiones anteriores a 1.0.4.102, R7000P versiones anteriores a 1.3.2.126, R6700v3 versiones anteriores a 1.0.4.102 y a R6900P versiones anteriores a 1.3.2.126"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6
},
{
"source": "cve@mitre.org",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL"
},
"exploitabilityScore": 3.9,
"impactScore": 5.2
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.0
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-200"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.0.11.110",
"matchCriteriaId": "82B05B23-A689-4A0A-8569-9FA7972EA663"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.0.4.30",
"matchCriteriaId": "B6364559-B141-43AE-B40A-506B79BCC3AA"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.0.4.62",
"matchCriteriaId": "A6C5E300-92E2-447A-822F-B95D1C59530E"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:rs400_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.5.1.80",
"matchCriteriaId": "95AF0FA9-F2C5-4D84-BF37-AA8CB6EC3C4A"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:rs400:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2700644E-0940-4D05-B3CA-904D91739E58"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:r6400v2_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.0.4.102",
"matchCriteriaId": "19E991D4-ADE8-4EFC-A405-DBAF07FFEB21"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:r6400v2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AFE6B3A8-0601-44EA-AD9B-3BDDE6654FDF"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.3.2.126",
"matchCriteriaId": "182AB5A2-5D07-4A5E-A863-4EE216D6F423"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:r6700v3_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.0.4.102",
"matchCriteriaId": "611768C9-4B1D-42CC-97CF-78D05EA332AC"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:r6700v3:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C88DA385-5FAE-49EC-80D6-78F81E7EEC16"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.3.2.126",
"matchCriteriaId": "44801589-B49E-4B00-84DD-EFE47526C70C"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A"
}
]
}
]
}
],
"references": [
{
"url": "https://kb.netgear.com/000064459/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-Routers-PSV-2020-0117",
"source": "cve@mitre.org",
"tags": [
"Patch",
"Vendor Advisory"
]
}
]
}