"id": "CVE-2024-50696",
|
|
"sourceIdentifier": "cve@mitre.org",
|
|
"published": "2025-02-26T21:15:17.997",
|
|
"lastModified": "2025-04-07T18:48:52.107",
|
|
"vulnStatus": "Analyzed",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "SunGrow WiNet-S V200.001.00.P025 and earlier versions is missing integrity checks for firmware upgrades. Sending a specific MQTT message allows an update to an inverter or a WiNet connectivity dongle with a bogus firmware file that is located on attacker-controlled server."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "SunGrow WiNet-S V200.001.00.P025 y las versiones anteriores les faltan comprobaciones de integridad para las actualizaciones de firmware. El env\u00edo de un mensaje MQTT espec\u00edfico permite una actualizaci\u00f3n de un inversor o un dispositivo de conectividad WiNet con un archivo de firmware falso que se encuentra en un servidor controlado por el atacante."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
|
|
"baseScore": 7.5,
|
|
"baseSeverity": "HIGH",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "NONE",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "NONE"
|
|
},
|
|
"exploitabilityScore": 3.9,
|
|
"impactScore": 3.6
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
|
"type": "Secondary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-494"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:sungrowpower:winet-s_firmware:*:*:*:*:*:*:*:*",
|
|
"versionEndIncluding": "200.001.00.P025",
|
|
"matchCriteriaId": "271D759A-8B61-44BF-B164-792D2874CBC3"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:sungrowpower:winet-s:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "30D17448-43BC-46D6-87E8-B67F5FBBDFB5"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://en.sungrowpower.com/security-notice-detail-2/6140",
|
|
"source": "cve@mitre.org",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |