2025-04-07 20:04:58 +00:00

93 lines
2.8 KiB
JSON

{
"id": "CVE-2024-50696",
"sourceIdentifier": "cve@mitre.org",
"published": "2025-02-26T21:15:17.997",
"lastModified": "2025-04-07T18:48:52.107",
"vulnStatus": "Analyzed",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "SunGrow WiNet-S V200.001.00.P025 and earlier versions is missing integrity checks for firmware upgrades. Sending a specific MQTT message allows an update to an inverter or a WiNet connectivity dongle with a bogus firmware file that is located on attacker-controlled server."
},
{
"lang": "es",
"value": "SunGrow WiNet-S V200.001.00.P025 y las versiones anteriores les faltan comprobaciones de integridad para las actualizaciones de firmware. El env\u00edo de un mensaje MQTT espec\u00edfico permite una actualizaci\u00f3n de un inversor o un dispositivo de conectividad WiNet con un archivo de firmware falso que se encuentra en un servidor controlado por el atacante."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"availabilityImpact": "NONE"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6
}
]
},
"weaknesses": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-494"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:sungrowpower:winet-s_firmware:*:*:*:*:*:*:*:*",
"versionEndIncluding": "200.001.00.P025",
"matchCriteriaId": "271D759A-8B61-44BF-B164-792D2874CBC3"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:sungrowpower:winet-s:-:*:*:*:*:*:*:*",
"matchCriteriaId": "30D17448-43BC-46D6-87E8-B67F5FBBDFB5"
}
]
}
]
}
],
"references": [
{
"url": "https://en.sungrowpower.com/security-notice-detail-2/6140",
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
]
}
]
}