René Helmke 7791f18b51 bootstrap
2023-05-16 16:09:41 +02:00

119 lines
3.2 KiB
JSON

{
"id": "CVE-2017-5249",
"sourceIdentifier": "cve@rapid7.con",
"published": "2018-02-22T16:29:00.280",
"lastModified": "2019-10-09T23:28:15.510",
"vulnStatus": "Modified",
"descriptions": [
{
"lang": "en",
"value": "In version 6.1.0.19 and prior of Wink Labs's Wink - Smart Home Android app, the OAuth token used by the app to authorize user access is not stored in an encrypted and secure manner."
},
{
"lang": "es",
"value": "En la versi\u00f3n 6.1.0.19 y anteriores de la aplicaci\u00f3n para Android Wink Labs's Wink - Smart Home, el token OAuth empleado por la app para autorizar el acceso de los usuarios no se almacena de forma cifrada y segura."
}
],
"metrics": {
"cvssMetricV30": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.0
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-312"
},
{
"lang": "en",
"value": "CWE-922"
}
]
},
{
"source": "cve@rapid7.con",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-922"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:wink:wink:*:*:*:*:*:android:*:*",
"versionEndIncluding": "6.1.0.19",
"matchCriteriaId": "B9B6FB51-A07C-4828-AAA7-B3ABCABFB1D8"
}
]
}
]
}
],
"references": [
{
"url": "https://blog.rapid7.com/2017/09/22/multiple-vulnerabilities-in-wink-and-insteon-smart-home-systems/",
"source": "cve@rapid7.con",
"tags": [
"Third Party Advisory"
]
}
]
}