René Helmke 7791f18b51 bootstrap
2023-05-16 16:09:41 +02:00

117 lines
3.7 KiB
JSON

{
"id": "CVE-2019-12611",
"sourceIdentifier": "cve@mitre.org",
"published": "2019-10-17T19:15:10.483",
"lastModified": "2019-10-22T15:16:28.087",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in Bitdefender BOX firmware versions before 2.1.37.37-34 that affects the general reliability of the product. Specially crafted packets sent to the miniupnpd implementation in result in the device allocating memory without freeing it later. This behavior can cause the miniupnpd component to crash or to trigger a device reboot."
},
{
"lang": "es",
"value": "Se detect\u00f3 un problema en Bitdefender BOX versiones de firmware anteriores a 2.1.37.37-34 que afecta la confiabilidad general del producto. Los paquetes especialmente dise\u00f1ados enviados hacia la implementaci\u00f3n miniupnpd resultan en que el dispositivo asigne memoria sin liberar m\u00e1s tarde. Este comportamiento puede causar que el componente miniupnpd bloquee o active el reinicio del dispositivo."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "HIGH",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "HIGH",
"baseScore": 4.4,
"baseSeverity": "MEDIUM"
},
"exploitabilityScore": 0.8,
"impactScore": 3.6
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:L/AC:L/Au:N/C:N/I:N/A:C",
"accessVector": "LOCAL",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 4.9
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 3.9,
"impactScore": 6.9,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-770"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:bitdefender:box_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.1.37.37-34",
"matchCriteriaId": "6EAC4F45-4E09-4782-B6D2-28B857F5A59C"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:bitdefender:box:-:*:*:*:*:*:*:*",
"matchCriteriaId": "51BC3E15-5AA6-4353-BA9D-C5FB975544C2"
}
]
}
]
}
],
"references": [
{
"url": "https://www.bitdefender.com/support/security-advisories/bitdefender-box-denial-service-va-3184/",
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
]
}
]
}