René Helmke 7791f18b51 bootstrap
2023-05-16 16:09:41 +02:00

195 lines
5.4 KiB
JSON

{
"id": "CVE-2019-20666",
"sourceIdentifier": "cve@mitre.org",
"published": "2020-04-15T20:15:13.693",
"lastModified": "2020-04-20T14:25:43.433",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by stored XSS. This affects RBR50 before 2.3.5.30, RBS50 before 2.3.5.30, and RBK50 before 2.3.5.30."
},
{
"lang": "es",
"value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una vulnerabilidad de tipo XSS almacenado. Esto afecta a RBR50 versiones anteriores a 2.3.5.30, RBS50 versiones anteriores a 2.3.5.30 y RBK50 versiones anteriores a 2.3.5.30."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "HIGH",
"userInteraction": "REQUIRED",
"scope": "CHANGED",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"availabilityImpact": "NONE",
"baseScore": 4.8,
"baseSeverity": "MEDIUM"
},
"exploitabilityScore": 1.7,
"impactScore": 2.7
}
],
"cvssMetricV30": [
{
"source": "cve@mitre.org",
"type": "Secondary",
"cvssData": {
"version": "3.0",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:N",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "HIGH",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "NONE",
"baseScore": 6.0,
"baseSeverity": "MEDIUM"
},
"exploitabilityScore": 0.8,
"impactScore": 5.2
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"accessVector": "NETWORK",
"accessComplexity": "MEDIUM",
"authentication": "SINGLE",
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"availabilityImpact": "NONE",
"baseScore": 3.5
},
"baseSeverity": "LOW",
"exploitabilityScore": 6.8,
"impactScore": 2.9,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": true
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-79"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:rbr50_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.3.5.30",
"matchCriteriaId": "094B04D5-9063-4D7A-B367-E1F2688B3667"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:rbr50:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B2CAEA32-6934-4743-9E6B-22D52AC5E7F8"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:rbs50_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.3.5.30",
"matchCriteriaId": "C489444C-6C19-4A52-AF66-A1D48ADC4F26"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:rbs50:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3BCFD959-D522-4FA0-AD01-2937DAEE1EDF"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:rbk50_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.3.5.30",
"matchCriteriaId": "B7ED1541-DE7D-4A4C-B8D1-CB42E52E3DBE"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:rbk50:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8BA66D07-D017-49D6-8E72-5C48E940DE1B"
}
]
}
]
}
],
"references": [
{
"url": "https://kb.netgear.com/000061473/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-WiFi-Systems-PSV-2018-0555",
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
]
}
]
}