René Helmke 7791f18b51 bootstrap
2023-05-16 16:09:41 +02:00

195 lines
5.5 KiB
JSON

{
"id": "CVE-2019-20695",
"sourceIdentifier": "cve@mitre.org",
"published": "2020-04-16T19:15:23.650",
"lastModified": "2021-07-21T11:39:23.747",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by disclosure of sensitive information. This affects SRK60 before 2.3.5.106, SRR60 before 2.3.5.106, and SRS60 before 2.3.5.106."
},
{
"lang": "es",
"value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una divulgaci\u00f3n de informaci\u00f3n confidencial. Esto afecta a SRK60 versiones anteriores a 2.3.5.106, SRR60 versiones anteriores a 2.3.5.106 y SRS60 versiones anteriores a 2.3.5.106."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6
}
],
"cvssMetricV30": [
{
"source": "cve@mitre.org",
"type": "Secondary",
"cvssData": {
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "LOW",
"baseScore": 9.4,
"baseSeverity": "CRITICAL"
},
"exploitabilityScore": 3.9,
"impactScore": 5.5
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.0
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:srk60_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.3.5.106",
"matchCriteriaId": "4D271876-60E0-4419-93AA-3BBDC3E02BCD"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:srk60:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DCC347EB-699E-4626-A944-2D378101DDCF"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:srr60_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.3.5.106",
"matchCriteriaId": "FE1922A1-06DD-4598-8F57-933747CCB311"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:srr60:-:*:*:*:*:*:*:*",
"matchCriteriaId": "55E6F589-04DA-431C-9E03-BA2A59BB0E4A"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:srs60_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.3.5.106",
"matchCriteriaId": "24BA1EF1-C594-41E9-B091-C55B0997E110"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:srs60:-:*:*:*:*:*:*:*",
"matchCriteriaId": "BFB01247-A20F-41CA-8718-E8E60E7F14B3"
}
]
}
]
}
],
"references": [
{
"url": "https://kb.netgear.com/000061234/Security-Advisory-for-Sensitive-Information-Disclosure-on-Orbi-Pro-WiFi-System-PSV-2019-0158",
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
]
}
]
}