"id": "CVE-2019-20699",
"sourceIdentifier": "cve@mitre.org",
"published": "2020-04-16T19:15:23.900",
"lastModified": "2020-04-21T14:11:11.677",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects GS105Ev2 before 1.6.0.4, GS105PE before 1.6.0.4, GS408EPP before 1.0.0.15, GS808E before 1.7.0.7, GS908E before 1.7.0.3, GSS108E before 1.6.0.4, and GSS108EPP before 1.0.0.15."
},
{
"lang": "es",
"value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer por parte de un atacante no autenticado. Esto afecta a GS105Ev2 versiones anteriores a 1.6.0.4, GS105PE versiones anteriores a 1.6.0.4, GS408EPP versiones anteriores a 1.0.0.15, GS808E versiones anteriores a 1.7.0.7, GS908E versiones anteriores a 1.7.0.3, GSS108E versiones anteriores a 1.6.0.4, y GSS108EPP versiones anteriores a 1.0.0.15."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
}
],
"cvssMetricV30": [
{
"source": "cve@mitre.org",
"type": "Secondary",
"cvssData": {
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5
},
"baseSeverity": "HIGH",
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-120"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:gs105e_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.6.0.4",
"matchCriteriaId": "FBF196D1-A0B3-443D-88A0-AA2E096C57F6"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:gs105e:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "DD993BAB-DF89-41AB-936B-9C6F280BAE1D"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:gs105pe_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.6.0.4",
"matchCriteriaId": "F0E0CE18-6EA8-41F5-8984-1FEB91561127"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:gs105pe:-:*:*:*:*:*:*:*",
"matchCriteriaId": "211D1DBE-5D7A-4309-A125-126AF2A16647"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:gs408epp_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.0.0.15",
"matchCriteriaId": "A902F828-C55A-45B9-81D5-641FFE0ACD2D"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:gs408epp:-:*:*:*:*:*:*:*",
"matchCriteriaId": "86E8C803-F6E4-4CFD-B9BA-D83A7C5269E9"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:gs808e_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.7.0.7",
"matchCriteriaId": "D0DC63B1-22DB-4509-A468-9D1B63C997E7"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:gs808e:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4FBE41AE-2001-4539-9F63-710EDEE42629"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:gs908e_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.7.0.3",
"matchCriteriaId": "7D4E120D-3609-40F0-86B3-E7A2BC774D40"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:gs908e:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F6CA61D2-1B85-4C5F-86CA-AB1F877243FA"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:gss108e_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.6.0.4",
"matchCriteriaId": "3350D6E6-522C-4D9F-9D74-EE3A2FB9177E"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:gss108e:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8244C4BA-F166-4C32-BF43-0964CD99921B"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:gss108epp_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.0.0.15",
"matchCriteriaId": "E2106BBF-F216-4CBE-915C-B9680BB8B4EC"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:gss108epp:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2EF32417-92E9-4D8B-913A-539A473A2673"
}
]
}
]
}
],
"references": [
{
"url": "https://kb.netgear.com/000061230/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Switches-PSV-2018-0538",
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
]
}
]
}