René Helmke 7791f18b51 bootstrap
2023-05-16 16:09:41 +02:00

158 lines
4.8 KiB
JSON

{
"id": "CVE-2019-8269",
"sourceIdentifier": "vulnerability@kaspersky.com",
"published": "2019-03-08T23:29:00.657",
"lastModified": "2020-10-19T17:56:47.387",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "UltraVNC revision 1206 has stack-based Buffer overflow vulnerability in VNC client code inside FileTransfer module, which leads to a denial of service (DoS) condition. This attack appear to be exploitable via network connectivity. This vulnerability has been fixed in revision 1207."
},
{
"lang": "es",
"value": "UltraVNC, en su revisi\u00f3n 1206, tiene un desbordamiento de b\u00fafer basado en pila en el c\u00f3digo del cliente VNC dentro del m\u00f3dulo \"FileTransfer\", lo cual conduce a una condici\u00f3n de denegaci\u00f3n de servicio (DoS). Este ataque parece ser explotable mediante la conectividad de red. Esta vulnerabilidad se ha solucionado en la revisi\u00f3n 1207."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
},
{
"source": "vulnerability@kaspersky.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-121"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:uvnc:ultravnc:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.2.2.3",
"matchCriteriaId": "555D034F-3D64-4ED1-9B63-F8D59199E99C"
}
]
}
]
},
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:sinumerik_access_mymachine\\/p2p:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.8",
"matchCriteriaId": "D9345335-DF62-4472-93CD-E2C85453F91E"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:sinumerik_pcu_base_win10_software\\/ipc:*:*:*:*:*:*:*:*",
"versionEndExcluding": "14.00",
"matchCriteriaId": "7498412D-79FD-43FE-AD9B-5820FB5CF7D8"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:sinumerik_pcu_base_win7_software\\/ipc:*:*:*:*:*:*:*:*",
"versionEndIncluding": "12.01",
"matchCriteriaId": "1F603341-03C5-46CA-8A74-EC5A50135194"
}
]
}
]
}
],
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf",
"source": "vulnerability@kaspersky.com",
"tags": [
"Third Party Advisory"
]
},
{
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-016-ultravnc-stack-based-buffer-overflow/",
"source": "vulnerability@kaspersky.com",
"tags": [
"Third Party Advisory"
]
},
{
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06",
"source": "vulnerability@kaspersky.com",
"tags": [
"Third Party Advisory",
"US Government Resource"
]
}
]
}