mirror of
https://github.com/fkie-cad/nvd-json-data-feeds.git
synced 2025-05-28 09:11:28 +00:00
113 lines
3.0 KiB
JSON
113 lines
3.0 KiB
JSON
{
|
|
"id": "CVE-2022-30079",
|
|
"sourceIdentifier": "cve@mitre.org",
|
|
"published": "2022-09-08T12:15:08.617",
|
|
"lastModified": "2022-12-09T17:17:13.937",
|
|
"vulnStatus": "Analyzed",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Command injection vulnerability was discovered in Netgear R6200 v2 firmware through R6200v2-V1.0.3.12 via binary /sbin/acos_service that could allow remote authenticated attackers the ability to modify values in the vulnerable parameter."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Se ha detectado una vulnerabilidad de inyecci\u00f3n de comandos en el firmware Netgear R6200 v2 por medio de R6200v2-V1.0.3.12, por medio del binario /sbin/acos_service, que podr\u00eda permitir a atacantes remotos autenticados la capacidad de modificar valores en el par\u00e1metro vulnerable"
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "LOW",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 8.8,
|
|
"baseSeverity": "HIGH"
|
|
},
|
|
"exploitabilityScore": 2.8,
|
|
"impactScore": 5.9
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-77"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:netgear:r6200:r6200v2-v1.0.3.12:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "28027BC8-02CE-4E00-B677-08399A29A7F6"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:netgear:r6200:v2:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "719248B0-BE22-4836-A23E-FE9F7590FB0C"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "http://netgear.com",
|
|
"source": "cve@mitre.org",
|
|
"tags": [
|
|
"Product"
|
|
]
|
|
},
|
|
{
|
|
"url": "http://r6200v2.com",
|
|
"source": "cve@mitre.org",
|
|
"tags": [
|
|
"Broken Link"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://github.com/10TG/vulnerabilities/blob/main/Netgear/CVE-2022-30079/CVE-2022-30079.md",
|
|
"source": "cve@mitre.org",
|
|
"tags": [
|
|
"Exploit",
|
|
"Third Party Advisory"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://www.netgear.com/about/security/",
|
|
"source": "cve@mitre.org",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |