"id": "CVE-2024-47942",
"sourceIdentifier": "productcert@siemens.com",
"published": "2024-11-12T13:15:11.427",
"lastModified": "2024-11-13T23:15:21.497",
"vulnStatus": "Analyzed",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 9). The affected applications suffer from a DLL hijacking vulnerability. This could allow an attacker to execute arbitrary code via placing a crafted DLL file on the system."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en Solid Edge SE2024 (todas las versiones anteriores a V224.0 Update 9). Las aplicaciones afectadas sufren una vulnerabilidad de secuestro de DLL. Esto podr\u00eda permitir que un atacante ejecute c\u00f3digo arbitrario colocando un archivo DLL manipulado espec\u00edficamente para ello en el sistema."
}
],
"metrics": {
"cvssMetricV40": [
{
"source": "productcert@siemens.com",
"type": "Primary",
"cvssData": {
"version": "4.0",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"baseScore": 7.0,
"baseSeverity": "HIGH",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "LOW",
"userInteraction": "PASSIVE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"subAvailabilityImpact": "NONE",
"exploitMaturity": "NOT_DEFINED",
"confidentialityRequirement": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"availabilityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"valueDensity": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED"
}
}
],
"cvssMetricV31": [
{
"source": "productcert@siemens.com",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 1.3,
"impactScore": 5.9
}
]
},
"weaknesses": [
{
"source": "productcert@siemens.com",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-427"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:solid_edge_se2024:*:*:*:*:*:*:*:*",
"versionEndExcluding": "224.00.09.04",
"matchCriteriaId": "D4CDE696-132C-46B7-B285-C83CE0AD4D55"
}
]
}
]
}
],
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-351178.html",
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
]
}
]
}