"id": "CVE-2010-5307",
"sourceIdentifier": "cve@mitre.org",
"published": "2015-08-04T14:59:10.517",
"lastModified": "2018-03-28T01:29:01.417",
"vulnStatus": "Modified",
"descriptions": [
{
"lang": "en",
"value": "The HIPAA configuration interface in GE Healthcare Optima MR360 has a password of (1) operator for the root account, (2) adw2.0 for the admin account, and (3) adw2.0 for the sdc account, which has unspecified impact and attack vectors. NOTE: it is not clear whether these passwords are default, hardcoded, or dependent on another system or product that requires a fixed value."
},
{
"lang": "es",
"value": "Vulnerabilidad en la configuraci\u00f3n de la interfaz HIPAA en GE Healthcare Optima MR360 tiene una contrase\u00f1a de (1) operador para la cuenta root, (2) adw2.0 para la cuenta del administrador y (3) adw2.0 para la cuenta sdc, lo cual tiene un impacto y vectores de ataque no especificados. NOTA: no est\u00e1 claro si esta contrase\u00f1a es por defecto, embebida o dependiente de otro sistema o producto que requiera un valor fijo."
}
],
"metrics": {
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0
},
"baseSeverity": "HIGH",
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"acInsufInfo": true,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-255"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:gehealthcare:optima_mr360_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F6056690-0318-4110-BF67-2F6B6455A1EA"
}
]
}
]
}
],
"references": [
{
"url": "http://apps.gehealthcare.com/servlet/ClientServlet/MR360+operator+manual+paper.pdf?REQ=RAA&DIRECTION=5339461-1EN&FILENAME=MR360%2Boperator%2Bmanual%2Bpaper.pdf&FILEREV=4&DOCREV_ORG=4",
"source": "cve@mitre.org"
},
{
"url": "http://www.forbes.com/sites/thomasbrewster/2015/07/10/vulnerable-breasts/",
"source": "cve@mitre.org"
},
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-037-02",
"source": "cve@mitre.org"
},
{
"url": "https://twitter.com/digitalbond/status/619250429751222277",
"source": "cve@mitre.org"
}
]
}