René Helmke 7791f18b51 bootstrap
2023-05-16 16:09:41 +02:00

129 lines
3.8 KiB
JSON

{
"id": "CVE-2018-14789",
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"published": "2018-08-22T18:29:00.433",
"lastModified": "2022-04-22T19:23:00.013",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "In Philips' IntelliSpace Cardiovascular (ISCV) products (ISCV Version 3.1 or prior and Xcelera Version 4.1 or prior), an unquoted search path or element vulnerability has been identified, which may allow an attacker to execute arbitrary code and escalate their level of privileges."
},
{
"lang": "es",
"value": "En los productos IntelliSpace Cardiovascular (ISCV) de Phillips (ISCV en versiones 2.x o anteriores y Xcelera en versiones 4.1 y anteriores), se ha identificado una vulnerabilidad de elemento o ruta de b\u00fasqueda sin entrecomillar en la que un atacante podr\u00eda ejecutar c\u00f3digo arbitrario y escalar su nivel de privilegios."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "HIGH",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM"
},
"exploitabilityScore": 0.8,
"impactScore": 5.9
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
"accessVector": "LOCAL",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"availabilityImpact": "PARTIAL",
"baseScore": 4.6
},
"baseSeverity": "MEDIUM",
"exploitabilityScore": 3.9,
"impactScore": 6.4,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-428"
}
]
},
{
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-428"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:philips:intellispace_cardiovascular:*:*:*:*:*:*:*:*",
"versionEndIncluding": "3.1",
"matchCriteriaId": "C11159E7-9244-49B2-933A-AAF995D4AAF6"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:philips:xcelera:*:*:*:*:*:*:*:*",
"versionEndIncluding": "4.1",
"matchCriteriaId": "FEE47A78-BC37-427F-8B8B-81E0EB380C1C"
}
]
}
]
}
],
"references": [
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-226-01",
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Third Party Advisory",
"US Government Resource"
]
},
{
"url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security",
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Vendor Advisory"
]
}
]
}