"id": "CVE-2018-4841",
"sourceIdentifier": "productcert@siemens.com",
"published": "2018-03-29T13:29:00.210",
"lastModified": "2024-11-21T04:07:33.813",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in TIM 1531 IRC (All versions < V1.1). A remote attacker with network access to port 80/tcp or port 443/tcp could perform administrative operations on the device without prior authentication. Successful exploitation could allow to cause a denial-of-service, or read and manipulate data as well as configuration settings of the affected device. At the stage of publishing this security advisory no public exploitation is known. Siemens provides mitigations to resolve it."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en TIM 1531 IRC (todas las versiones anteriores a V1.1). Un atacante remoto con acceso de red al puerto 80/tcp o al puerto 443/tcp podr\u00eda realizar operaciones administrativas en el dispositivo sin autenticaci\u00f3n anterior. La explotaci\u00f3n exitosa de esta vulnerabilidad podr\u00eda permitir una denegaci\u00f3n de servicio (DoS) o la lectura y manipulaci\u00f3n de datos como las opciones de configuraci\u00f3n del dispositivo afectado. En el momento de publicaci\u00f3n de este advisory de seguridad, no se conoce ninguna explotaci\u00f3n p\u00fablica. Siemens proporciona mitigaciones para resolver este problema de seguridad."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"baseScore": 10.0,
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"availabilityImpact": "COMPLETE"
},
"baseSeverity": "HIGH",
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "productcert@siemens.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-303"
}
]
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-287"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:siemens:tim_1531_irc_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.1",
"matchCriteriaId": "9AE61932-8868-48B9-A2F7-286BA6F0DA6B"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:siemens:tim_1531_irc:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C1D94BEB-BBFB-4258-9835-87DBBB999239"
}
]
}
]
}
],
"references": [
{
"url": "http://www.securityfocus.com/bid/103576",
"source": "productcert@siemens.com",
"tags": [
"Broken Link",
"Third Party Advisory",
"VDB Entry"
]
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-110922.pdf",
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
]
},
{
"url": "http://www.securityfocus.com/bid/103576",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Broken Link",
"Third Party Advisory",
"VDB Entry"
]
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-110922.pdf",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
]
}
]
}