"id": "CVE-2025-27398",
|
|
"sourceIdentifier": "productcert@siemens.com",
|
|
"published": "2025-03-11T10:15:19.247",
|
|
"lastModified": "2025-03-11T10:15:19.247",
|
|
"vulnStatus": "Awaiting Analysis",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0). Affected devices do not properly neutralize special characters when interpreting user controlled log paths.\r\nThis could allow an authenticated highly-privileged remote attacker to execute a limited set of binaries that are already present on the filesystem."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Se ha identificado una vulnerabilidad en SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (todas las versiones anteriores a la V4.0). Los dispositivos afectados no neutralizan correctamente los caracteres especiales al interpretar las rutas de registro controladas por el usuario. Esto podr\u00eda permitir que un atacante remoto autenticado y con privilegios elevados ejecute un conjunto limitado de archivos binarios que ya est\u00e1n presentes en el sistema de archivos."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV40": [
|
|
{
|
|
"source": "productcert@siemens.com",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "4.0",
|
|
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
|
|
"baseScore": 2.1,
|
|
"baseSeverity": "LOW",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"attackRequirements": "PRESENT",
|
|
"privilegesRequired": "HIGH",
|
|
"userInteraction": "NONE",
|
|
"vulnConfidentialityImpact": "NONE",
|
|
"vulnIntegrityImpact": "LOW",
|
|
"vulnAvailabilityImpact": "NONE",
|
|
"subConfidentialityImpact": "NONE",
|
|
"subIntegrityImpact": "NONE",
|
|
"subAvailabilityImpact": "NONE",
|
|
"exploitMaturity": "NOT_DEFINED",
|
|
"confidentialityRequirement": "NOT_DEFINED",
|
|
"integrityRequirement": "NOT_DEFINED",
|
|
"availabilityRequirement": "NOT_DEFINED",
|
|
"modifiedAttackVector": "NOT_DEFINED",
|
|
"modifiedAttackComplexity": "NOT_DEFINED",
|
|
"modifiedAttackRequirements": "NOT_DEFINED",
|
|
"modifiedPrivilegesRequired": "NOT_DEFINED",
|
|
"modifiedUserInteraction": "NOT_DEFINED",
|
|
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
|
|
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
|
|
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
|
|
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
|
|
"modifiedSubIntegrityImpact": "NOT_DEFINED",
|
|
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
|
|
"Safety": "NOT_DEFINED",
|
|
"Automatable": "NOT_DEFINED",
|
|
"Recovery": "NOT_DEFINED",
|
|
"valueDensity": "NOT_DEFINED",
|
|
"vulnerabilityResponseEffort": "NOT_DEFINED",
|
|
"providerUrgency": "NOT_DEFINED"
|
|
}
|
|
}
|
|
],
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "productcert@siemens.com",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:N",
|
|
"baseScore": 2.7,
|
|
"baseSeverity": "LOW",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "HIGH",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "NONE",
|
|
"integrityImpact": "LOW",
|
|
"availabilityImpact": "NONE"
|
|
},
|
|
"exploitabilityScore": 1.2,
|
|
"impactScore": 1.4
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "productcert@siemens.com",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-78"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/html/ssa-075201.html",
|
|
"source": "productcert@siemens.com"
|
|
}
|
|
]
|
|
} |