mirror of
https://github.com/fkie-cad/nvd-json-data-feeds.git
synced 2025-06-12 02:04:49 +00:00
126 lines
4.0 KiB
JSON
126 lines
4.0 KiB
JSON
{
|
|
"id": "CVE-2022-39136",
|
|
"sourceIdentifier": "productcert@siemens.com",
|
|
"published": "2022-11-08T11:15:11.247",
|
|
"lastModified": "2023-06-13T09:15:14.517",
|
|
"vulnStatus": "Modified",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A vulnerability has been identified in JT2Go (All versions < V14.1.0.4), Teamcenter Visualization V13.2 (All versions < V13.2.0.12), Teamcenter Visualization V13.3 (All versions < V13.3.0.7), Teamcenter Visualization V13.3 (All versions >= V13.3.0.7 < V13.3.0.8), Teamcenter Visualization V14.0 (All versions < V14.0.0.3), Teamcenter Visualization V14.1 (All versions < V14.1.0.4). The affected application is vulnerable to fixed-length heap-based buffer while parsing specially crafted TIF files. An attacker could leverage this vulnerability to execute code in the context of the current process."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
|
|
"attackVector": "LOCAL",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "REQUIRED",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 7.8,
|
|
"baseSeverity": "HIGH"
|
|
},
|
|
"exploitabilityScore": 1.8,
|
|
"impactScore": 5.9
|
|
},
|
|
{
|
|
"source": "productcert@siemens.com",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
|
|
"attackVector": "LOCAL",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "REQUIRED",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 7.8,
|
|
"baseSeverity": "HIGH"
|
|
},
|
|
"exploitabilityScore": 1.8,
|
|
"impactScore": 5.9
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-787"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"source": "productcert@siemens.com",
|
|
"type": "Secondary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-122"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "14.1.0.4",
|
|
"matchCriteriaId": "FD5EAF75-B0F4-4792-9833-085B9D830FCE"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
|
|
"versionEndIncluding": "13.3.0.7",
|
|
"matchCriteriaId": "68C38035-5616-4F26-BB00-CE837B353144"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
|
|
"versionStartIncluding": "14.0",
|
|
"versionEndExcluding": "14.0.0.3",
|
|
"matchCriteriaId": "0F811DB6-3650-4BCB-A538-AAECF63EA085"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
|
|
"versionStartIncluding": "14.1",
|
|
"versionEndExcluding": "14.1.0.4",
|
|
"matchCriteriaId": "175648D0-81ED-4AC9-AF2D-4C9E93814C36"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-120378.pdf",
|
|
"source": "productcert@siemens.com",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |