"id": "CVE-2022-48221",
"sourceIdentifier": "cve@mitre.org",
"published": "2023-04-04T15:15:08.717",
"lastModified": "2023-04-11T15:36:47.963",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in Acuant AcuFill SDK before 10.22.02.03. Multiple MSI's get executed out of a standard-user writable directory. Through a race condition and OpLock manipulation, these files can be overwritten by a standard user. They then get executed by the elevated installer. This gives a standard user full SYSTEM code execution (elevation of privileges)."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "NETWORK",
"attackComplexity": "HIGH",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 1.6,
"impactScore": 5.9
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-362"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:gbgplc:acuant_acufill_sdk:*:*:*:*:*:*:*:*",
"versionEndExcluding": "10.22.02.03",
"matchCriteriaId": "C982B4DA-273F-4B30-B931-2988851C07A5"
}
]
}
]
}
],
"references": [
{
"url": "https://acuant.com",
"source": "cve@mitre.org",
"tags": [
"Not Applicable"
]
},
{
"url": "https://hackandpwn.com/disclosures/CVE-2022-48221.pdf",
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
]
}
]
}