"id": "CVE-2021-40367",
"sourceIdentifier": "productcert@siemens.com",
"published": "2024-01-04T12:15:22.830",
"lastModified": "2024-01-10T17:03:28.070",
"vulnStatus": "Analyzed",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in syngo fastView (All versions). The affected application lacks proper validation of user-supplied data when parsing DICOM files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15097)"
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en syngo fastView (todas las versiones). La aplicaci\u00f3n afectada carece de una validaci\u00f3n adecuada de los datos proporcionados por el usuario al analizar archivos DICOM. Esto podr\u00eda dar como resultado una escritura fuera de los l\u00edmites m\u00e1s all\u00e1 del final de una estructura asignada. Un atacante podr\u00eda aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual. (ZDI-CAN-15097)"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
},
{
"source": "productcert@siemens.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
}
]
},
"weaknesses": [
{
"source": "productcert@siemens.com",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens-healthineers:syngo_fastview:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B7D9A743-3BE4-4523-B34F-0C8461D3C63A"
}
]
}
]
}
],
"references": [
{
"url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-688797",
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
]
}
]
}