"id": "CVE-2018-11106",
"sourceIdentifier": "cve@mitre.org",
"published": "2020-04-01T17:15:14.737",
"lastModified": "2020-08-24T17:37:01.140",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "NETGEAR has released fixes for a pre-authentication command injection in request_handler.php security vulnerability on the following product models: WC7500, running firmware versions prior to 6.5.3.5; WC7520, running firmware versions prior to 2.5.0.46; WC7600v1, running firmware versions prior to 6.5.3.5; WC7600v2, running firmware versions prior to 6.5.3.5; and WC9500, running firmware versions prior to 6.5.3.5."
},
{
"lang": "es",
"value": "NETGEAR presenta correcciones publicadas para una inyecci\u00f3n de comando previa a la autenticaci\u00f3n en una vulnerabilidad de seguridad del archivo request_handler.php en los siguientes modelos de producto: WC7500, ejecutando versiones de firmware anteriores a 6.5.3.5; WC7520, ejecutando versiones de firmware anteriores a 2.5.0.46; WC7600v1, ejecutando versiones de firmware anteriores a 6.5.3.5; WC7600v2, ejecutando versiones de firmware anteriores a 6.5.3.5; y WC9500, ejecutando versiones de firmware anteriores a 6.5.3.5."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0
},
"baseSeverity": "HIGH",
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-77"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:wc7500_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "6.5.3.5",
"matchCriteriaId": "8184DF48-1CCE-4950-921B-8A825D8CDD71"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:wc7500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EB22B065-8EC8-4DA7-984A-CCB6919AF8F3"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:wc7520_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.5.0.46",
"matchCriteriaId": "86CD35ED-0A90-4932-976B-A7666B3D7C7A"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:wc7520:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A58C9FE8-4BD5-41F9-9714-2D8083A51D98"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:wc7600v1_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "6.5.3.5",
"matchCriteriaId": "3D3D43A9-6A00-4498-BEC5-46A11604A1A6"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:wc7600v1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8EB1A3EC-1069-40FC-BDDF-C3AC93E037C5"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:wc7600v2_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "6.5.3.5",
"matchCriteriaId": "EB9D9CAF-D9FC-4E42-9C80-DE53C75AD578"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:wc7600v2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4C8BB1F1-A12D-43CC-A6D0-9633E99D746B"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:netgear:wc9500_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "6.5.3.5",
"matchCriteriaId": "8073AB91-0F60-4EF8-9347-EB0EA6C76A76"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:netgear:wc9500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "113D0DF6-C719-4A43-80B2-463EC4323009"
}
]
}
]
}
],
"references": [
{
"url": "https://kb.netgear.com/000058243/Security-Advisory-for-Pre-Authentication-Command-Injection-in-request-handler-php-on-Some-Wireless-Controllers-PSV-2018-0051",
"source": "cve@mitre.org",
"tags": [
"Patch",
"Vendor Advisory"
]
}
]
}