"id": "CVE-2022-36526",
|
|
"sourceIdentifier": "cve@mitre.org",
|
|
"published": "2022-08-15T17:15:14.000",
|
|
"lastModified": "2022-08-18T17:19:40.780",
|
|
"vulnStatus": "Analyzed",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "D-Link GO-RT-AC750 GORTAC750_revA_v101b03 & GO-RT-AC750_revB_FWv200b02 is vulnerable to Authentication Bypass via function phpcgi_main in cgibin."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "D-Link GO-RT-AC750 versiones GORTAC750_revA_v101b03 & GO-RT-AC750_revB_FWv200b02 son vulnerables a una omisi\u00f3n de autenticaci\u00f3n por medio de la funci\u00f3n phpcgi_main en cgibin."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "NONE",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "NONE",
|
|
"baseScore": 7.5,
|
|
"baseSeverity": "HIGH"
|
|
},
|
|
"exploitabilityScore": 3.9,
|
|
"impactScore": 3.6
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-287"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:dlink:go-rt-ac750_firmware:101b03:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "11857770-E809-483A-993F-1C827428B334"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:dlink:go-rt-ac750:revision_a:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "426BE281-6336-4A4E-892B-CE8BBCA8ABF7"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:dlink:go-rt-ac750_firmware:200b02:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "E610B4D9-198B-4986-89CC-F3C75DBC3EF3"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:dlink:go-rt-ac750:revision_b:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "5F4EF05A-EF25-4E60-8A08-9C0CDD9244EF"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "http://d-link.com",
|
|
"source": "cve@mitre.org",
|
|
"tags": [
|
|
"Broken Link",
|
|
"Product"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://drive.google.com/file/d/1ji5Ph6c-qgp0lBvbY8BZJjeqbju3VeK8/view?usp=sharing",
|
|
"source": "cve@mitre.org",
|
|
"tags": [
|
|
"Broken Link",
|
|
"Third Party Advisory"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://www.dlink.com/en/security-bulletin/",
|
|
"source": "cve@mitre.org",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |