2024-06-16 02:03:09 +00:00

59 lines
2.0 KiB
JSON

{
"id": "CVE-2024-35211",
"sourceIdentifier": "productcert@siemens.com",
"published": "2024-06-11T12:15:17.643",
"lastModified": "2024-06-11T13:54:12.057",
"vulnStatus": "Awaiting Analysis",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V1.2). The affected web server, after a successful login, sets the session cookie on the browser, without applying any security attributes (such as \u201cSecure\u201d, \u201cHttpOnly\u201d, or \u201cSameSite\u201d)."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (Todas las versiones &lt; V1.2). El servidor web afectado, despu\u00e9s de iniciar sesi\u00f3n correctamente, establece la cookie de sesi\u00f3n en el navegador, sin aplicar ning\u00fan atributo de seguridad (como \"Secure\", \"HttpOnly\" o \"SameSite\")."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "productcert@siemens.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6
}
]
},
"weaknesses": [
{
"source": "productcert@siemens.com",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-614"
}
]
}
],
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-196737.html",
"source": "productcert@siemens.com"
}
]
}