"id": "CVE-2023-2638",
|
|
"sourceIdentifier": "PSIRT@rockwellautomation.com",
|
|
"published": "2023-06-13T21:15:09.983",
|
|
"lastModified": "2024-11-21T07:58:58.830",
|
|
"vulnStatus": "Modified",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "\nRockwell Automation's FactoryTalk System Services does not verify that a backup configuration archive is password protected.\n\n\u00a0\n\nImproper authorization in FTSSBackupRestore.exe may lead to the loading of malicious configuration archives.\u00a0 This vulnerability may allow a local, authenticated non-admin user to craft a malicious backup archive, without password protection, that will be loaded by FactoryTalk System Services as a valid backup when a restore procedure takes places. User interaction is required for this vulnerability to be successfully exploited.\n\n\n"
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "PSIRT@rockwellautomation.com",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:N/I:N/A:H",
|
|
"baseScore": 5.9,
|
|
"baseSeverity": "MEDIUM",
|
|
"attackVector": "LOCAL",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "LOW",
|
|
"userInteraction": "REQUIRED",
|
|
"scope": "CHANGED",
|
|
"confidentialityImpact": "NONE",
|
|
"integrityImpact": "NONE",
|
|
"availabilityImpact": "HIGH"
|
|
},
|
|
"exploitabilityScore": 1.5,
|
|
"impactScore": 4.0
|
|
},
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:N/I:H/A:N",
|
|
"baseScore": 5.0,
|
|
"baseSeverity": "MEDIUM",
|
|
"attackVector": "LOCAL",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "LOW",
|
|
"userInteraction": "REQUIRED",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "NONE",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "NONE"
|
|
},
|
|
"exploitabilityScore": 1.3,
|
|
"impactScore": 3.6
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "PSIRT@rockwellautomation.com",
|
|
"type": "Secondary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-287"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-287"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:rockwellautomation:factorytalk_policy_manager:6.11.0:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "78D6F03E-E110-4CA7-8883-5CE38FF8E5A0"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:rockwellautomation:factorytalk_system_services:6.11.0:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "46A50229-56B5-4B30-8B4A-6D180D65C2D6"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1139683",
|
|
"source": "PSIRT@rockwellautomation.com",
|
|
"tags": [
|
|
"Permissions Required",
|
|
"Vendor Advisory"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1139683",
|
|
"source": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"tags": [
|
|
"Permissions Required",
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |