"id": "CVE-2023-2638",
"sourceIdentifier": "PSIRT@rockwellautomation.com",
"published": "2023-06-13T21:15:09.983",
"lastModified": "2024-11-21T07:58:58.830",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "\nRockwell Automation's FactoryTalk System Services does not verify that a backup configuration archive is password protected.\n\n\u00a0\n\nImproper authorization in FTSSBackupRestore.exe may lead to the loading of malicious configuration archives.\u00a0 This vulnerability may allow a local, authenticated non-admin user to craft a malicious backup archive, without password protection, that will be loaded by FactoryTalk System Services as a valid backup when a restore procedure takes places. User interaction is required for this vulnerability to be successfully exploited.\n\n\n"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "PSIRT@rockwellautomation.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:N/I:N/A:H",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "REQUIRED",
"scope": "CHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 1.5,
"impactScore": 4.0
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:N/I:H/A:N",
"baseScore": 5.0,
"baseSeverity": "MEDIUM",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"availabilityImpact": "NONE"
},
"exploitabilityScore": 1.3,
"impactScore": 3.6
}
]
},
"weaknesses": [
{
"source": "PSIRT@rockwellautomation.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-287"
}
]
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-287"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:rockwellautomation:factorytalk_policy_manager:6.11.0:*:*:*:*:*:*:*",
"matchCriteriaId": "78D6F03E-E110-4CA7-8883-5CE38FF8E5A0"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:rockwellautomation:factorytalk_system_services:6.11.0:*:*:*:*:*:*:*",
"matchCriteriaId": "46A50229-56B5-4B30-8B4A-6D180D65C2D6"
}
]
}
]
}
],
"references": [
{
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1139683",
"source": "PSIRT@rockwellautomation.com",
"tags": [
"Permissions Required",
"Vendor Advisory"
]
},
{
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1139683",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Permissions Required",
"Vendor Advisory"
]
}
]
}