"id": "CVE-2023-27976",
|
|
"sourceIdentifier": "cybersecurity@se.com",
|
|
"published": "2023-04-18T17:15:07.287",
|
|
"lastModified": "2024-11-21T07:53:51.340",
|
|
"vulnStatus": "Modified",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "\nA CWE-668: Exposure of Resource to Wrong Sphere vulnerability exists that could cause\nremote code execution when a valid user visits a malicious link provided through the web\nendpoints. Affected Products:\u00a0EcoStruxure Control Expert (V15.1 and above)"
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "cybersecurity@se.com",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
|
|
"baseScore": 8.8,
|
|
"baseSeverity": "HIGH",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "REQUIRED",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH"
|
|
},
|
|
"exploitabilityScore": 2.8,
|
|
"impactScore": 5.9
|
|
},
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
|
|
"baseScore": 8.8,
|
|
"baseSeverity": "HIGH",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "REQUIRED",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH"
|
|
},
|
|
"exploitabilityScore": 2.8,
|
|
"impactScore": 5.9
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "cybersecurity@se.com",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-668"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*",
|
|
"versionStartIncluding": "15.1",
|
|
"matchCriteriaId": "F00F06FE-58DA-4882-A7E8-0D7E1597026A"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-101-03.pdf",
|
|
"source": "cybersecurity@se.com"
|
|
},
|
|
{
|
|
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-101-03.pdf",
|
|
"source": "af854a3a-2127-422b-91ae-364da2661108"
|
|
}
|
|
]
|
|
} |