"id": "CVE-2023-27984",
|
|
"sourceIdentifier": "cybersecurity@se.com",
|
|
"published": "2023-03-21T11:15:10.553",
|
|
"lastModified": "2024-11-21T07:53:52.320",
|
|
"vulnStatus": "Modified",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A CWE-20: Improper Input Validation vulnerability exists in Custom Reports that could cause a macro to be executed, potentially leading to remote code execution when a user opens a malicious report file planted by an attacker. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior)."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "cybersecurity@se.com",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
|
|
"baseScore": 7.8,
|
|
"baseSeverity": "HIGH",
|
|
"attackVector": "LOCAL",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "REQUIRED",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH"
|
|
},
|
|
"exploitabilityScore": 1.8,
|
|
"impactScore": 5.9
|
|
},
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
|
|
"baseScore": 8.8,
|
|
"baseSeverity": "HIGH",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "REQUIRED",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH"
|
|
},
|
|
"exploitabilityScore": 2.8,
|
|
"impactScore": 5.9
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "cybersecurity@se.com",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-20"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:schneider-electric:custom_reports:*:*:*:*:*:*:*:*",
|
|
"versionEndIncluding": "16.0.0.23040",
|
|
"matchCriteriaId": "93DB1B65-C1B5-4A20-ACA7-84EE9C07E9B1"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:schneider-electric:igss_dashboard:*:*:*:*:*:*:*:*",
|
|
"versionEndIncluding": "16.0.0.23040",
|
|
"matchCriteriaId": "CCB39F06-042F-444C-819B-709FF63E060F"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:schneider-electric:igss_data_server:*:*:*:*:*:*:*:*",
|
|
"versionEndIncluding": "16.0.0.23040",
|
|
"matchCriteriaId": "AE9B5271-999B-4B2B-B4F3-8D99B3A78077"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-073-04.pdf",
|
|
"source": "cybersecurity@se.com",
|
|
"tags": [
|
|
"Patch",
|
|
"Vendor Advisory"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-073-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-073-04.pdf",
|
|
"source": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"tags": [
|
|
"Patch",
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |